  Comparison of Secretory Responses as Measured by Membrane Capacitance and by Amperometry

Haller, M., Heinemann, C., Chow, R. H., Heidelberger, R., & Neher, E. (1998). Comparison of Secretory Responses as Measured by Membrane Capacitance and by Amperometry. Biophysical Journal, 74(4), 2100-2113. doi:10.1016/S0006-3495(98)77917-2.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
1-s2.0-S0006349598779172-main.pdf (出版社版), 258KB
 
ファイルのパーマリンク:
-
ファイル名:
1-s2.0-S0006349598779172-main.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き ( Max Planck Society (every institute); )
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Haller, M.1, 著者
Heinemann, C.1, 著者           
Chow, R. H.1, 著者           
Heidelberger, R.1, 著者
Neher, E.1, 著者           
所属:
1Department of Membrane Biophysics, MPI for biophysical chemistry, Max Planck Society, ou_578579              

内容説明

表示:
非表示:
キーワード: -
 要旨: We have compared capacitance and amperometric measurements in bovine chromaffin cells when secretion was elicited by flash photolysis of caged-calcium or step depolarizations. Total amperometric charge depended linearly on the amount of capacitance increase in both types of experiments. Furthermore, the properties of resolvable amperometric spikes after flashes were comparable to those observed after depolarizations, and their timing was compatible with the rate of capacitance increase. For a more detailed comparison, we used Monte Carlo simulations of multiple amperometric events occurring randomly over the surface of a sphere and summing together, to generate a reference amperometric signal for a given measured capacitance increase. Even after correction for endocytotic processes, the time courses of the integrated experimental records lagged behind the integrated Monte Carlo records by ∼50 ms in flash and depolarization experiments. This delay was larger by ∼40 ms than what can be expected from the “pre-foot delay” or the foot duration. Possible sources for the remaining delay could be diffusional barriers like the patch-pipette and the chamber bottom, which are not taken into account in the model. We also applied a novel type of fluctuation analysis to estimate the relative quantum size of an amperometric event. On average the estimates from experimental amperometric traces, in both flash and depolarization experiments, were 3–5 times smaller than estimates from simulated ones. This discrepancy can be due to contributions to the amperometric current from small vesicles, preferred release from cellular regions orientated toward the chamber bottom, or abundance of “foot-only” events. In conclusion, amperometric signals in flash and depolarization experiments displayed similar delayed average time courses and a lower estimate for the relative quantum size compared to the modeled amperometric signals. However, individual amperometric spikes were in agreement with expectations derived from capacitance signals.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 1998
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/S0006-3495(98)77917-2
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Biophysical Journal
  その他 : Biophys. J.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Cambridge, Mass. : Cell Press
ページ: - 巻号: 74 (4) 通巻号: - 開始・終了ページ: 2100 - 2113 識別子(ISBN, ISSN, DOIなど): ISSN: 0006-3495
CoNE: https://pure.mpg.de/cone/journals/resource/954925385117