日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  On the synchronization of transcranial magnetic stimulation and functional echo-planar imaging

Bestmann, S., Baudewig, J., & Frahm, J. (2003). On the synchronization of transcranial magnetic stimulation and functional echo-planar imaging. Journal of Magnetic Resonance Imaging, 17(3), 309-316. Retrieved from http://www3.interscience.wiley.com/cgi-bin/fulltext/102531266/PDFSTART.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
599254.pdf (出版社版), 2MB
ファイルのパーマリンク:
https://hdl.handle.net/11858/00-001M-0000-0028-EEE2-9
ファイル名:
599254.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Bestmann, S.1, 著者           
Baudewig, J., 著者
Frahm, J.1, 著者           
所属:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

内容説明

表示:
非表示:
キーワード: magnetic resonance imaging; transcranial magnetic stimulation; human brain; BOLD; RF excitation; functional echo-planar imaging
 要旨: Purpose: To minimize artifacts in echo-planar imaging (EPI) of human brain function introduced by simultaneous transcranial magnetic stimulation (TMS). Materials and Methods: Distortions due to TMS pulses (0.25 msec, 2.0 T) were studied at 2.0 T before and during EPI. Results: Best results were obtained if both the EPI section orientation and the frequency-encoding gradient were parallel to the plane of the TMS coil. Under these conditions, a TMS pulse caused image distortions when preceding the EPI sequence by less than 100 msec. Recordings with a magnetic field gradient pick-up coil revealed transient magnetic fields after TMS, which are generated by eddy currents in the TMS coil. TMS during image acquisition completely spoiled all transverse magnetizations and induced disturbances ranging from image corruption to mild image blurring, depending on the affected low and high spatial frequencies. Simultaneous TMS and radio-frequency (RF) excitation gave rise to T1- dependent signal changes that lasted for several seconds and yielded pronounced false-positive activations during functional brain mapping. Conclusion: To ensure reliable and robust combinations, TMS should be applied at least 100 msec before EPI while completely avoiding any pulses during imaging.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2003-03
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 20737
URI: http://www3.interscience.wiley.com/cgi-bin/fulltext/102531266/PDFSTART
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Magnetic Resonance Imaging
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 17 (3) 通巻号: - 開始・終了ページ: 309 - 316 識別子(ISBN, ISSN, DOIなど): -