Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  The GEO 600 status

Grote, H., & LIGO Scientific Collaboration (2010). The GEO 600 status. Classical and Quantum Gravity, 27: 084003. doi:10.1088/0264-9381/27/8/084003.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
CQG_27_8_084003.pdf (beliebiger Volltext), 1012KB
Name:
CQG_27_8_084003.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Grote, Hartmut1, Autor           
LIGO Scientific Collaboration , Autor              
Affiliations:
1Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The British–German gravitational wave detector GEO 600 has concluded a long observational period called Astrowatch, which lasted from November 2007 to July 2009. Together with the LIGO-H2 detector, GEO 600 was kept observing, while other detectors of the world-wide network of laser-interferometers like LIGO(L1 and H1) and Virgo were upgraded. A fraction of the time during the astrowatch period was set apart for noise investigations and experiments preparing future upgrades. Even with these investigations GEO 600 reached an observation time of 86.0% of the overall time, such that a total of 522 days worth of data were collected. The average sensitivity was roughly a factor of 2 lower than that of the LIGO-H2 detector for frequencies above 500 Hz. In July 2009 GEO 600 has started an upgrade program called GEO-HF. Within this program we aim at improving the sensitivity by a number of sequential upgrades, like tuned signal recycling, DC readout, output mode-cleaning, injection of squeezed vacuum states and the increase of circulating light power. Tuned signal recycling and DC readout have already been implemented and can be operated robustly, due to a new technique associated with the automatic alignment system.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2010
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1088/0264-9381/27/8/084003
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Classical and Quantum Gravity
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Bristol, U.K. : Institute of Physics
Seiten: - Band / Heft: 27 Artikelnummer: 084003 Start- / Endseite: - Identifikator: Anderer: 954925513480
Anderer: 0264-9381