  Simultaneous mapping of water shift and B-1(WASABI)-Application to field-inhomogeneity correction of CEST MRI data.

Schuenke, P., Windschuh, J., Roeloffs, V. B., Ladd, M. E., Bachert, P., & Zaiss, M. (2017). Simultaneous mapping of water shift and B-1(WASABI)-Application to field-inhomogeneity correction of CEST MRI data. Magnetic Resonance in Medicine, 77(2), 571-580. doi:10.1002/mrm.26133.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
2424516.pdf (出版社版), 2MB
ファイルのパーマリンク:
https://hdl.handle.net/11858/00-001M-0000-002D-0A6A-B
ファイル名:
2424516.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-
:
2424516_Suppl.docx (付録資料), 228KB
ファイルのパーマリンク:
https://hdl.handle.net/11858/00-001M-0000-002D-0A6B-9
ファイル名:
2424516_Suppl.docx
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/vnd.openxmlformats-officedocument.wordprocessingml.document / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Schuenke, P., 著者
Windschuh, J., 著者
Roeloffs, V. B.1, 著者           
Ladd, M. E., 著者
Bachert, P., 著者
Zaiss, M., 著者
所属:
1Biomedical NMR Research GmbH, MPI for Biophysical Chemistry, Max Planck Society, ou_578634              

内容説明

表示:
非表示:
キーワード: field mapping; B0 mapping; B 1 mapping; WASABI; CEST
 要旨: Purpose Together with the development of MRI contrasts that are inherently small in their magnitude, increased magnetic field accuracy is also required. Hence, mapping of the static magnetic field (B0) and the excitation field (B1) is not only important to feedback shim algorithms, but also for postprocess contrast-correction procedures. Methods A novel field-inhomogeneity mapping method is presented that allows simultaneous mapping of the water shift and B1 (WASABI) using an off-resonant rectangular preparation pulse. The induced Rabi oscillations lead to a sinc-like spectrum in the frequency-offset dimension and allow for determination of B0 by its symmetry axis and of B1 by its oscillation frequency. Results Stability of the WASABI method with regard to the influences of T1, T2, magnetization transfer, and repetition time was investigated and its convergence interval was verified. B0 and B1 maps obtained simultaneously by means of WASABI in the human brain at 3 T and 7 T can compete well with maps obtained by standard methods. Finally, the method was applied successfully for B0 and B1 correction of chemical exchange saturation transfer MRI (CEST-MRI) data of the human brain. Conclusion The proposed WASABI method yields a novel simultaneous B0 and B1 mapping within 1 min that is robust and easy to implement. Magn Reson Med 77:571–580, 2017. © 2016 International Society for Magnetic Resonance in Medicine

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2016-02-092017-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.26133
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 77 (2) 通巻号: - 開始・終了ページ: 571 - 580 識別子(ISBN, ISSN, DOIなど): -