日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Effect of fringe-artifact correction on sub-tomogram averaging from Zernike phase-plate cryo-TEM

Kishchenko, G. P., Danev, R., Fisher, R., He, J., Hsieh, C., Marko, M., & Sui, H. (2015). Effect of fringe-artifact correction on sub-tomogram averaging from Zernike phase-plate cryo-TEM. JOURNAL OF STRUCTURAL BIOLOGY, 191(3), 299-305. doi:10.1016/j.jsb.2015.07.009.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Kishchenko, Gregory P.1, 著者
Danev, Radostin2, 著者           
Fisher, Rebecca1, 著者
He, Jie1, 著者
Hsieh, Chyongere1, 著者
Marko, Michael1, 著者
Sui, Haixin1, 著者
所属:
1external, ou_persistent22              
2Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565142              

内容説明

表示:
非表示:
キーワード: TRANSMISSION ELECTRON-MICROSCOPY; CONTRAST CRYOELECTRON MICROSCOPY; MOLECULAR ARCHITECTURE; RADIAL SPOKES; UCSF CHIMERA; IN-SITU; FLAGELLA; VISUALIZATION; EM; RECONSTRUCTIONSElectron tomography; Zernike phase-plate; Sub-volume averaging; Image processing;
 要旨: Zernike phase-plate (ZPP) imaging greatly increases contrast in cryo-electron microscopy, however fringe artifacts appear in the images. A computational de-fringing method has been proposed, but it has not been widely employed, perhaps because the importance of de-fringing has not been clearly demonstrated. For testing purposes, we employed Zernike phase-plate imaging in a cryo-electron tomographic study of radial-spoke complexes attached to microtubule doublets. We found that the contrast enhancement by ZPP imaging made nonlinear denoising insensitive to the filtering parameters, such that simple low-frequency band-pass filtering made the same improvement in map quality. We employed sub-tomogram averaging, which compensates for the effect of the "missing wedge" and considerably improves map quality. We found that fringes (caused by the abrupt cut-on of the central hole in the phase plate) can lead to incorrect representation of a structure that is well-known from the literature. The expected structure was restored by amplitude scaling, as proposed in the literature. Our results show that de-fringing is an important part of image-processing for cryo-electron tomography of macromolecular complexes with ZPP imaging. (C) 2015 Elsevier Inc. All rights reserved.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2015
 出版の状態: 出版
 ページ: 7
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): ISI: 000360599200005
DOI: 10.1016/j.jsb.2015.07.009
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: JOURNAL OF STRUCTURAL BIOLOGY
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: 525 B ST, STE 1900, SAN DIEGO, CA 92101-4495 USA : ACADEMIC PRESS INC ELSEVIER SCIENCE
ページ: - 巻号: 191 (3) 通巻号: - 開始・終了ページ: 299 - 305 識別子(ISBN, ISSN, DOIなど): ISSN: 1047-8477