Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Scanning Fluorescence Correlation Spectroscopy (SFCS) with a Scan Path Perpendicular to the Membrane Plane

Müller, P., Schwille, P., & Weidemann, T. (2014). Scanning Fluorescence Correlation Spectroscopy (SFCS) with a Scan Path Perpendicular to the Membrane Plane. In Y. Engelborghs, & A. Visser (Eds.), Fluorescence Spectroscopy and Microscopy (pp. 635-651). Totowa: Humana Press.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Buchkapitel
Untertitel : protocol

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Müller, Paul1, Autor
Schwille, Petra2, Autor           
Weidemann, Thomas2, Autor           
Affiliations:
1external, ou_persistent22              
2Schwille, Petra / Cellular and Molecular Biophysics, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565169              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Scanning fluorescence correlation spectroscopy (SFCS) Fluorescence correlation spectroscopy (FCS) Fluorescence cross-correlation spectroscopy (FCCS) Membrane diffusion Giant unilamellar vesicles (GUV) Diffusion Protein–protein interaction Ligand binding
 Zusammenfassung: Scanning fluorescence correlation spectroscopy (SFCS) with a scan path
perpendicular to the membrane plane was introduced to measure diffusion
and interactions of fluorescent components in free-standing
biomembranes. Using a confocal laser scanning microscope (CLSM), the
open detection volume is repeatedly scanned through the membrane at a
kHz frequency. The fluorescence photons emitted from the detection
volume are continuously recorded and stored in a file. While the
accessory hardware requirements for a conventional CLSM are minimal,
data evaluation can pose a bottleneck. The photon events must be
assigned to each scan, in which the maximum signal intensities have to
be detected, binned, and aligned between the scans, in order to derive
the membrane-related intensity fluctuations of one spot. Finally, this
time-dependent signal must be correlated and evaluated by well-known FCS
model functions. Here we provide two platform-independent, open source
software tools (PyScanFCS and PyCorrFit) that allow to perform all of
these steps and to establish perpendicular SFCS in its one- or two-focus
as well as its single- or dual-color modality.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2014
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: ISI: 000328374800030
DOI: 10.1007/978-1-62703-649-8_29
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Fluorescence Spectroscopy and Microscopy
  Andere : Methods in Molecular Biology (Methods and Protocols), vol 1076
Genre der Quelle: Buch
 Urheber:
Engelborghs, Y., Herausgeber
Visser, A., Herausgeber
Affiliations:
-
Ort, Verlag, Ausgabe: Totowa : Humana Press
Seiten: - Band / Heft: - Artikelnummer: - Start- / Endseite: 635 - 651 Identifikator: ISBN: 978-1-62703-648-1

Quelle 2

einblenden:
ausblenden:
Titel: Methods in Molecular Biology
  Andere : Methods in Molecular Biology (Methods and Protocols)
Genre der Quelle: Reihe
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Totowa : Humana Press
Seiten: - Band / Heft: 1076 Artikelnummer: - Start- / Endseite: - Identifikator: ISSN: 1064-3745