  Surface modification of PDMS microfluidic devices by controlled sulfuric acid treatment and the application in chip electrophoresis

Gitlin, L., Schulze, P., Ohla, S., Bongard, H.-J., & Belder, D. (2015). Surface modification of PDMS microfluidic devices by controlled sulfuric acid treatment and the application in chip electrophoresis. Electrophoresis, 36(3), 449-456. doi:10.1002/elps.201400269.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Gitlin, Leonid1, 2, 著者           
Schulze, Philipp2, 著者           
Ohla, Stefan1, 3, 著者           
Bongard, Hans-Josef4, 著者           
Belder, Detlev1, 5, 著者           
所属:
1Institut für Analytische Chemie, Universität Leipzig, Leipzig, Germany, ou_persistent22              
2Service Department Schulze (GC, HPLC), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445630              
3Service Department Schulze (GC, HPLC), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_persistent22              
4Service Department Lehmann (EMR), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445625              
5Research Group Belder, Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445595              

内容説明

表示:
非表示:
キーワード: Molecular adsorption; PDMS; Sulfuric acid; Surface modification
 要旨: Herein, we present a straightforward surface modification technique for PDMS-based microfluidic devices. The method takes advantage of the high reactivity of concentrated sulfuric acid to enhance the surface properties of PDMS bulk material. This results in alteration of the surface morphology and chemical composition that is in-depth characterized by ATR-FTIR, EDX, SEM, and XPS. In comparison to untreated PDMS, modified substrates exhibit a significantly reduced diffusive uptake of small organic molecules while retaining its low electroosmotic properties. This was demonstrated by exposing the channels of a microfluidic device to concentrated rhodamine B solution followed by fluorescence microscopy. The surface modification procedure was used to improve chip-based electrophoretic separations. Separation efficiencies of FITC-labeled amines/amino acids obtained in treated and untreated PDMS-devices as well as in glass chips were compared. We obtained higher efficiencies in H2SO4 treated PDMS chips compared to untreated ones but lower efficiencies than those obtained in commercial microfluidic glass devices.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2015-02-022015-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/elps.201400269
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Electrophoresis
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Weinheim, Germany : Verlag Chemie,
ページ: - 巻号: 36 (3) 通巻号: - 開始・終了ページ: 449 - 456 識別子(ISBN, ISSN, DOIなど): ISSN: 0173-0835
CoNE: https://pure.mpg.de/cone/journals/resource/954925486765