  Particle surface area dependence of mineral dust in immersion freezing mode: investigations with freely suspended drops in an acoustic levitator and a vertical wind tunnel

Diehl, K., Debertshäuser, M., Eppers, O., Schmithüsen, H., Mitra, S. K., & Borrmann, S. (2014). Particle surface area dependence of mineral dust in immersion freezing mode: investigations with freely suspended drops in an acoustic levitator and a vertical wind tunnel. Atmospheric Chemistry and Physics, 14(22), 12343-12355. doi:10.5194/acp-14-12343-2014.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Diehl, K.1, 著者
Debertshäuser, M.1, 著者
Eppers, O.1, 著者
Schmithüsen, H.1, 著者
Mitra, S. K.1, 著者
Borrmann, S.2, 著者           
所属:
1external, ou_persistent22              
2Particle Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826291              

内容説明

表示:
非表示:
キーワード: -
 要旨: The heterogeneous freezing temperatures of supercooled drops were measured using an acoustic levitator. This technique allows one to freely suspend single drops in the air without any wall contact. Heterogeneous nucleation by two types of illite (illite IMt1 and illite NX) and a montmorillonite sample was investigated in the immersion mode. Drops of 1mm in radius were monitored by a video camera while cooled down to -28 degrees C to simulate freezing within the tropospheric temperature range. The surface temperature of the drops was contact-free, determined with an infrared thermometer; the onset of freezing was indicated by a sudden increase of the drop surface temperature. For comparison, measurements with one particle type (illite NX) were additionally performed in the Mainz vertical wind tunnel with drops of 340 mu m radius freely suspended. Immersion freezing was observed in a temperature range between - 13 and -26 degrees C as a function of particle type and particle surface area immersed in the drops. Isothermal experiments in the wind tunnel indicated that after the cooling stage freezing still proceeds, at least during the investigated time period of 30 s. The results were evaluated by applying two descriptions of heterogeneous freezing, the stochastic and the singular model. Although the wind tunnel results do not support the time-independence of the freezing process both models are applicable for comparing the results from the two experimental techniques.

資料詳細

表示:
非表示:
言語:
 日付: 2014
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): ISI: 000345290700022
DOI: 10.5194/acp-14-12343-2014
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Atmospheric Chemistry and Physics
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Katlenburg-Lindau, Germany : European Geosciences Union
ページ: - 巻号: 14 (22) 通巻号: - 開始・終了ページ: 12343 - 12355 識別子(ISBN, ISSN, DOIなど): ISSN: 1680-7316
CoNE: https://pure.mpg.de/cone/journals/resource/111030403014016