日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  An online FT-ICR Penning-trap mass spectrometer for the DPS2-F section of the KATRIN experiment

Heck, M., Ascher, P., Cakirli, R. B., Golzke, H., Rodríguez, D., Stahl, S., Ubieto-Diaz, M., & Blaum, K. (2014). An online FT-ICR Penning-trap mass spectrometer for the DPS2-F section of the KATRIN experiment. Nuclear Instruments and Methods in Physics Research Section A, 757, 54-61. doi:10.1016/j.nima.2014.03.057.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Heck, Michael1, 著者           
Ascher , Pauline1, 著者
Cakirli, R. Burcu1, 2, 著者           
Golzke, Hendrik1, 3, 著者           
Rodríguez, D.4, 著者
Stahl, S.5, 著者
Ubieto-Diaz, Marta1, 6, 著者           
Blaum, Klaus1, 著者           
所属:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
2Department of Physics, University of Istanbul, Istanbul, Turkey, ou_persistent22              
3Karlsruhe Institute of Technologie, D-76021 Karlsruhe, Germany, ou_persistent22              
4Departamento de FísicaAtómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada, Spain, ou_persistent22              
5Stahl-Electronics, D-6Kellerweg 23, 7582 Mettenheim Germany, ou_persistent22              
6Leptosense Ltd., Friars Avenue, London SW153 DW, United Kingdom, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 MPINP: Speichertechnik - Abteilung Blaum
 要旨: Two Fourier-transform ion-cyclotron resonance (FT-ICR) Penning-trap mass spectrometers will be installed in the pumping section of the KArlsruhe TRItium Neutrino (KATRIN) experiment. This experiment aims at determining the electron anti-neutrino mass m(ν-e) with a sensitivity of 0.2 eV (90% C.L.) by high-resolution tritium β-spectroscopy. The tritium source creates various types of ions, which have to be reduced in order to reach the required low background level. The purpose of the FT-ICR mass spectrometers is the identification of the ion flux components as well as their abundance. Furthermore, the pumping efficiency of the differential pumping section DPS2-F can be determined since these Penning traps will be installed one at the entrance and one at the exit. In this paper the operation of the FT-ICR system is described. Experimental results are presented concerning the cryogenic broad-band amplifier system for the FT-ICR detection as well as the characterisation of the mass spectrometer with respect to, e.g., noise density and detection limit.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2014-04-05
 出版の状態: オンラインで出版済み
 ページ: 8
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/j.nima.2014.03.057
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Nuclear Instruments and Methods in Physics Research Section A
  その他 : Nucl. Instrum. Methods Phys. Res. A
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: North-Holland
ページ: - 巻号: 757 通巻号: - 開始・終了ページ: 54 - 61 識別子(ISBN, ISSN, DOIなど): ISSN: 0168-9002
CoNE: https://pure.mpg.de/cone/journals/resource/954925485716