日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  A new quasi-confocal image plate scanner with improved spatial resolution and ideal detection efficiency

Burmester, C., Braun, H. G., & Schröder, R. R. (1994). A new quasi-confocal image plate scanner with improved spatial resolution and ideal detection efficiency. Ultramicroscopy, 55(1), 55-65. doi:10.1016/0304-3991(94)90080-9.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
Ultramicroscopy_55_1994_55.pdf (全文テキスト(全般)), 2MB
 
ファイルのパーマリンク:
-
ファイル名:
Ultramicroscopy_55_1994_55.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (Max Planck Institute for Medical Research, MHMF; )
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

作成者

表示:
非表示:
 作成者:
Burmester, Christoph1, 著者           
Braun, H. G., 著者
Schröder, Rasmus R.1, 2, 著者           
所属:
1Emeritus Group Biophysics, Max Planck Institute for Medical Research, Max Planck Society, ou_1497712              
2Department of Biomolecular Mechanisms, Max Planck Institute for Medical Research, Max Planck Society, ou_1497700              

内容説明

表示:
非表示:
キーワード: -
 要旨: Image plates (IP) can be used for electron detection in the EM like conventional negative material [N. Mori et al., Ultramicroscopy 25 (1988) 195]. The stored information can later be retrieved by a scanning process in form of a digitized image. Although the physics of the electron storage process of the IPs in theory predicts electron detection with high spatial resolution, high detection efficiency and high dynamic range, in practice the scanning process limits resolution and detection efficiency. At present the scanners yield only moderate spatial resolution — about 100 μm effective pixel size (i.e. about 200 μm line resolution [S. Isoda et al., Ultramicroscopy 41 (1992) 99]. Data on the detection efficiency have not been published so far. Here we report a scanner of novel design with an improved optical detection device which gives highly increased spatial resolution (40 μm effective pixel size) and an optimal detection efficiency with a DQE of about 0.9. These properties are comparable to values published on slow-scan CCD cameras. Using subsequent scans of the same IP (which could register an image, an electron diffraction pattern or a parallel EELS recording) a linear dynamic detection range of almost 5 orders of magnitude is possible. We discuss how these properties of the IP scanner system could be utilized in future applications.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 1993-08-101994-02-282002-07-291994-07-01
 出版の状態: 出版
 ページ: 11
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 665180
DOI: 10.1016/0304-3991(94)90080-9
その他: 6890
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Ultramicroscopy
  省略形 : Ultramicroscopy
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : North-Holland
ページ: - 巻号: 55 (1) 通巻号: - 開始・終了ページ: 55 - 65 識別子(ISBN, ISSN, DOIなど): ISSN: 0304-3991
CoNE: https://pure.mpg.de/cone/journals/resource/954925512451