English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

Buonanno, A., & Chen, Y. (2004). Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers. Physical Review D, 69: 102004. doi:10.1103/PhysRevD.69.102004.

Item is

Files

show Files
hide Files
:
gr-qc_0310026.pdf (Preprint), 812KB
Name:
gr-qc_0310026.pdf
Description:
File downloaded from arXiv at 2014-04-10 13:07
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
:
PhysRevD.69.102004.pdf (Any fulltext), 2MB
Name:
PhysRevD.69.102004.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Buonanno, Alessandra1, 2, Author           
Chen, Yanbei, Author
Affiliations:
1Groupe de Gravitation et Cosmologie (GReCO), Institut d’Astrophysique de Paris (CNRS, ou_persistent22              
2Astrophysical and Cosmological Relativity, AEI-Golm, MPI for Gravitational Physics, Max Planck Society, ou_1933290              

Content

show
hide
Free keywords: General Relativity and Quantum Cosmology, gr-qc
 Abstract: We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]

Details

show
hide
Language(s):
 Dates: 2003-10-052004-03-092004
 Publication Status: Issued
 Pages: Figs. 9 and 12 corrected; Appendix added for narrowband data analysis
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Physical Review D
  Other : Phys. Rev. D.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Lancaster, Pa. : American Physical Society
Pages: - Volume / Issue: 69 Sequence Number: 102004 Start / End Page: - Identifier: ISSN: 0556-2821
CoNE: https://pure.mpg.de/cone/journals/resource/111088197762258