  Expanding the data depth for the analysis of complex crude oil samples by Fourier transform ion cyclotron resonance mass spectrometry using the spectral stitching method

Gaspar, A., & Schrader, W. (2012). Expanding the data depth for the analysis of complex crude oil samples by Fourier transform ion cyclotron resonance mass spectrometry using the spectral stitching method. Rapid Communications in Mass Spectrometry, (9), 1047-1052. doi:10.1002/rcm.6200.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Gaspar, Andras1, 著者           
Schrader, Wolfgang1, 著者           
所属:
1Service Department Schrader (MS), Max-Planck-Institut für Kohlenforschung, Max Planck Society, ou_1445629              

内容説明

表示:
非表示:
キーワード: -
 要旨: RATIONALE: Crude oil samples are very complex mixtures of compounds and only Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) provides the ultra-high mass resolution necessary to resolve them. However, FT-ICR MS operates best when only a small amount of ions is present during each transient. This cannot be accomplished with crude oil samples without chromatography because more than 50 000 compounds can be present, with the result that species with low intensity may be suppressed and are detected either with low intensity or not at all. METHODS: Spectral stitching was used to overcome the problems associated with suppression effects, where only short mass windows of 30 amu were scanned to reduce the amount of ions present in each individual scan. Afterwards, all the scans were co-added and the subsequent spectrum was used to calculate individual class distributions. RESULTS: A heavy crude oil sample was analyzed using spectral stitching and this approach was compared with analysis using a broadband-method in order to illustrate the enhancement in depth of information. Although both methods took the same analysis time a seven-times increase in the number of detected species was observed when the spectral stitching method was used compared with the commonly applied broadband method in a 900 amu mass window. CONCLUSIONS: Spectral stitching using smaller selected ion monitoring (SIM) windows for complex crude oil samples allows better class distribution to be obtained because less ion suppression is observed.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2012-02-132011-12-262012-02-132012-03-192012-05-15
 出版の状態: 出版
 ページ: 6
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1002/rcm.6200
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Rapid Communications in Mass Spectrometry
  その他 : Rapid Commun. Mass Spectrom.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York, NY : John Wiley & Sons
ページ: - 巻号: (9) 通巻号: - 開始・終了ページ: 1047 - 1052 識別子(ISBN, ISSN, DOIなど): ISSN: 0951-4198
CoNE: https://pure.mpg.de/cone/journals/resource/954925574961