日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Impact of image acquisition on voxel-based morphometry investigations of age-related structural brain changes

Streitbürger, D. P., Pampel, A., Krueger, G., Lepsien, J., Schroeter, M. L., Mueller, K., & Möller, H. E. (2014). Impact of image acquisition on voxel-based morphometry investigations of age-related structural brain changes. NeuroImage, 87, 170-182. doi:10.1016/j.neuroimage.2013.10.051.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Streitbürger, Daniel Paolo1, 著者           
Pampel, André1, 著者           
Krueger, Gunnar2, 著者
Lepsien, Jöran1, 著者           
Schroeter, Matthias L.3, 著者           
Mueller, Karsten1, 著者           
Möller, Harald E.1, 著者           
所属:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              
2Siemens Schweiz AG, Healthcare Sector IM & WS, Renens, Switzerland, ou_persistent22              
3Department Neurology, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634549              

内容説明

表示:
非表示:
キーワード: Aging; Imaging pulse sequence; Radiofrequency coil; Voxel size; Voxel-based morphometry
 要旨: A growing number of magnetic resonance imaging studies employ voxel-based morphometry (VBM) to assess structural brain changes. Recent reports have shown that image acquisition parameters may influence VBM results. For systematic evaluation, gray-matter-density (GMD) changes associated with aging were investigated by VBM employing acquisitions with different radiofrequency head coils (12-channel matrix coil vs. 32-channel array), different pulse sequences (MP-RAGE vs. MP2RAGE), and different voxel dimensions (1 mm vs. 0.8 mm). Thirty-six healthy subjects, classified as young, middle-aged, or elderly, participated in the study. Two-sample and paired t-tests revealed significant effects of acquisition parameters (coil, pulse sequence, and resolution) on the estimated age-related GMD changes in cortical and subcortical regions. Potential advantages in tissue classification and segmentation were obtained for MP2RAGE. The 32-channel coil generally outperformed the 12-channel coil, with more benefit for MP2RAGE. Further improvement can be expected from higher resolution if the loss in SNR is accounted for. Use of inconsistent acquisition parameters in VBM analyses is likely to introduce systematic bias. Overall, acquisition and protocol changes require careful adaptations of the VBM analysis strategy before generalized conclusion can be drawn.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2013-10-242013-11-022014-02-15
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/j.neuroimage.2013.10.051
PMID: 24188812
その他: Epub 2013
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NeuroImage
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 87 通巻号: - 開始・終了ページ: 170 - 182 識別子(ISBN, ISSN, DOIなど): ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166