日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Occupational Mercury Contamination Produces Loss of Color-and Contrast-Vision but no Effect in Full Field

Ventura, D., Simoes AL, Costa MTV, Costa MF, Souza JM, Canto-Pereira, L., Lago M, Faria, M., & Silveira, L. (2003). Occupational Mercury Contamination Produces Loss of Color-and Contrast-Vision but no Effect in Full Field. Poster presented at Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO 2003), Fort Lauderdale, FL, USA.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Ventura, DSF, 著者
Simoes AL, Costa MTV, Costa MF, Souza JM, Canto-Pereira, LH1, 著者           
Lago M, Faria, MAM, 著者
Silveira, LCL, 著者
所属:
1Department Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497797              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose: To assess the effect of mercury vapor exposure on visual function. Methods: Retired workers from a fluorescent lamp industry (n=24) were tested and compared to age-matched controls. Inclusion criteria were medical diagnosis of mercury contamination, with 20/20 Snellen VA and absence of known ophthalmological pathologies. Color vision was assessed with the following tests: FM-100 hue, Lanthony desaturated and Cambridge Colour Vision Test (Cambridge Research Systems Ltd). The sweep visual evoked potential system – sVEP (NuDiva2) using bipolar electrode placement was used to estimate contrast sensitivity. Full-field electroretinograms (ERG) were measured following the ISCEV protocol. All tests were performed monocularly in a darkened room. Results: Color vision loss was detected in 21/24 patients. Scores of patients ranged from 48 to 452 in the FM-100 test and from 152 to 302 in the Lanthony desaturated test and were statistically different from those of controls (p< 0.001). CCT ellipses of patients were significantly larger than those of controls in field 1 (p=0.02) and field 3 (p=0.01), but not in field 2 (p=0.07). Contrast sensitivity measured by the sVEP was reduced in all patients (n=14) relative to controls at the mid-frequency range - 0.8 (p<0.001), 2 (p=0.008) and 4 (p=0.01) cpd. No difference was found in contrast sensitivity at the lowest and highest spatial frequencies tested - 0.2, 15 and 30 cpd. Full-field ERG responses did not differ from controls in any of the ISCEV protocol test parameters. Conclusions: Visual function, assessed electrophysiologically by the VEP and also psychophysically, was clearly affected, in contrast to the ERG retinal function, suggesting central participation in the damage caused by mercury vapor exposure. More refined measurement of retinal function such as multifocal and pattern-ERG will be performed to investigate retinal damage.

資料詳細

表示:
非表示:
言語:
 日付: 2003-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 学位: -

関連イベント

表示:
非表示:
イベント名: Annual Meeting of the Association for Research in Vision and Ophthalmology (ARVO 2003)
開催地: Fort Lauderdale, FL, USA
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物

表示: