  Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans

Yacoub, E., Moortele, P., Shmuel, A., & Ugurbil, K. (2005). Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans. NeuroImage, 24(3), 738-750. doi:10.1016/j.neuroimage.2004.09.002.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Yacoub, E, 著者
Moortele, PFVD, 著者
Shmuel, A1, 著者           
Ugurbil, K, 著者
所属:
1External Organizations, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: At very high magnetic fields, GE BOLD fMRI is expected to contain nonspecific contributions and behave differently than HSE fMRI data. Similarly, the two approaches can conceivably suffer from different contributions to temporal instabilities in a times series that ultimately determine the contrast-to-noise ratio (CNR). We investigate the signal and signal fluctuation characteristics in GE and HSE fMRI data with the imaging parameters separately optimized for each contrast at 7 T. In HSE fMRI, activation-induced fractional signal change (ΔS/S) decreased rapidly, and the ratio of standard deviations of image-to-image fluctuations due to physiological processes (σPhys) to thermal noise (σTherm) remained constant with increasing voxel volume. In contrast, ΔS/S as well as volume of activated voxels was virtually independent of voxel size for GE BOLD, and σPhys/σTherm increased with increasing voxel size. The ratio of BOLD signal changes (GE/HSE) was much closer to 1 in tissue areas compared to vessel areas. These observations led to the conclusions that the spatial extent of the activation-induced ΔS/S was much broader in the GE data, and that the physiological processes that give rise to the temporal fluctuations lost coherence over millimeter distances in HSE compared to GE fMRI data. While further studies are needed to characterize it fully, σPhys in HSE data was clearly different than in GE data. It was concluded that HSE imaging yields a significantly reduced amount of nonspecific signals compared to GE imaging, and, would be the method of choice (over GE) for high-resolution applications in humans.

資料詳細

表示:
非表示:
言語:
 日付: 2005-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): BibTex参照ID: 4293
DOI: 10.1016/j.neuroimage.2004.09.002
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: NeuroImage
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Orlando, FL : Academic Press
ページ: - 巻号: 24 (3) 通巻号: - 開始・終了ページ: 738 - 750 識別子(ISBN, ISSN, DOIなど): ISSN: 1053-8119
CoNE: https://pure.mpg.de/cone/journals/resource/954922650166