日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  An online nano-liquid-chromatography tandem mass spectrometry (HPLC-MS/MS) with ultra low push-pull sampling for determining brain acetylcholine levels

Zhang, X., Rauch, A., Rainer, G., & Logothetis, N. (2006). An online nano-liquid-chromatography tandem mass spectrometry (HPLC-MS/MS) with ultra low push-pull sampling for determining brain acetylcholine levels. Poster presented at 17th International Mass Spectrometry Conference (IMSC 2006), Praha, Czech Republic.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Zhang, X1, 著者           
Rauch, A1, 著者           
Rainer, G1, 著者           
Logothetis, NK1, 著者           
所属:
1Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497798              

内容説明

表示:
非表示:
キーワード: -
 要旨: Acetylcholine (ACh) is believed to play a major role in attentional processing in cortex, thereby contributing to memory formation and maintenance. Monitoring ACh level-changes during behavior will help to understand their role in neuronal communication and function. In contrast to other highly sensitive detectors like electrochemistry (EC), which are commonly used in the monitoring of changes of extracellular brain fluid (EBF), mass-spectrometry methods enable direct determination of Ach without additional enzyme reactor. Here, a push and pull sampling method with flow rates in the range of nano-liters/min is used to reduce depletion of the EBF, allowing for lower flow rates compared to conventional microdialysis. To match the requirement to determine amounts of Ach in the attomole amount of acetylcholine from an EBF sample, a nano HPLC-MS/MS with semi online sampling system was set up and tested. The injection assembly included a high pressure injection pump and a series of computer-controlled nanopeak valves. For each injection a 250nl sample obtained in 5-min sampling interval was pumped out from the sampling capillary tubing. Chromatographic separation was performed on a capillary column of 75 µm I.D. Each HPLC run was finished in 7 min with a stepwise elution profile used for fast analysis. After the injection, the sample was trapped by flushing the column with pure water for 2 min, and subsequently with high concentration of acetonitrile favored by electrospray ionization MS. In-vitro test shows that acetylcholine could be detected with a low detection-limit of 30 attomole. By repeating this method in vivo we were able to reliably detect acetylcholine in the awake macaque. Future experiments will apply this methodology in combined neurochemical-electrophysiological experiments in behaving animals.

資料詳細

表示:
非表示:
言語:
 日付: 2006-09
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://imsc2006-abstracts.e-conference.info/abstract.php?ID=1061
BibTex参照ID: 4284
 学位: -

関連イベント

表示:
非表示:
イベント名: 17th International Mass Spectrometry Conference (IMSC 2006)
開催地: Praha, Czech Republic
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物

表示: