  Calf Muscles Imaged at BOLD MR: Correlation with TcPo2 and Flowmetry Measurements during Ischemia and Reactive Hyperemia-initial Experience

Ledermann, H., Heidecker H-G, Schulte A-C, Thalhammer C, Anschwanden M, Jaeger KA, Scheffler, K., & Bilecen, D. (2006). Calf Muscles Imaged at BOLD MR: Correlation with TcPo2 and Flowmetry Measurements during Ischemia and Reactive Hyperemia-initial Experience. Radiology, 241(2), 477-484. doi:10.1148/radiol.2412050701.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Ledermann, HP, 著者
Heidecker H-G, Schulte A-C, Thalhammer C, Anschwanden M, Jaeger KA, Scheffler, K1, 著者           
Bilecen, D, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose: To prospectively compare the blood oxygen level–dependent (BOLD) magnetic resonance (MR) signal intensity of calf muscle during ischemia and reactive hyperemia with laser Doppler flowmetry (LDF) and transcutaneous oxygen pressure (TcPo2) measurements, two parameters routinely used to evaluate peripheral arterial occlusive disease. Materials and Methods: The study was institutional review board approved; all volunteers gave informed consent. Fifteen healthy volunteers (eight male, seven female; mean age, 33.0 years ± 6.1 [standard deviation]) underwent LDF, TcPo2 measurement, and BOLD MR imaging of the calf during ischemia and reactive hyperemia. The BOLD signal intensity of the gastrocnemius muscle was measured at 1.5-T single-shot multiecho gradient-echo echo-planar imaging. Time to half ischemia minimum (THIM), time to half hyperemia peak (THHP), and time to peak (TTP) after cuff deflation were measured with each method. Correlation coefficients (CCs) for associations of BOLD response with LDF and TcPo2 time courses were calculated. Student t testing of key BOLD MR, LDF, and TcPo2 measurement parameters was performed. Results: During ischemia, normalized LDF and TcPo2 measurements decreased similarly to BOLD MR signal intensity (CCs: 0.86 and 0.96 for associations with LDF and TcPo2 measurements, respectively). Mean THIM values were 136.0, 82.5, and 121.3 seconds for BOLD MR, LDF (P < .01), and TcPo2 (P > .05) measurements, respectively. During early reactive hyperemia, LDF and TcPo2 measurements increased rapidly to peak values, similarly to BOLD MR signal intensity (CCs: 0.81 and 0.78, respectively). Mean THHP values were 26.0, 12.5, and 44.0 seconds for BOLD MR, LDF (P < .01), and TcPo2 (P < .01) measurements, respectively. Mean TTP values were 48.7, 47.5, and 98.0 seconds for BOLD MR, LDF (P > .05), and TcPo2 (P < .01) measurements, respectively. Conclusion: BOLD MR imaging of calf muscles—depending on underlying key parameters—has moderate to good correlation with LDF and TcPo2 measurements during ischemia and reactive hyperemia.

資料詳細

表示:
非表示:
言語:
 日付: 2006-11
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://radiology.rsna.org/content/241/2/477.full.pdf+html
DOI: 10.1148/radiol.2412050701
BibTex参照ID: LedermannHSTAJSB2006
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Radiology
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 241 (2) 通巻号: - 開始・終了ページ: 477 - 484 識別子(ISBN, ISSN, DOIなど): -