Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  SELOVS: Brain MRSI localization based on highly selective T1- and B1-insensitive outer-volume suppression at 3T

Henning, A., Schär, M., Schulte, R., Wilm, B., Pruessmann, K., & Boesiger, P. (2008). SELOVS: Brain MRSI localization based on highly selective T1- and B1-insensitive outer-volume suppression at 3T. Magnetic Resonance in Medicine, 59(1), 40-51. doi:10.1002/mrm.21374.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Henning, A1, Autor           
Schär, M, Autor
Schulte, RF, Autor
Wilm, B, Autor
Pruessmann, KP, Autor
Boesiger, P, Autor
Affiliations:
1Institute for Biomedical Engineering, University and ETH, Zurich, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: In vivo, high-field MR spectroscopic imaging (MRSI) profits from signal-to-noise ratio (SNR) gain and increased spectral resolution. However, bandwidth limitations of slice-selective excitation and refocusing pulses lead to strong chemical-shift displacement at high field strength when using conventional MRSI localization based on PRESS. Consequential metabolic information, particularly of border regions such as cortical brain tissue, is distorted. In addition, lipid contamination remains a major confound. To address these problems it is proposed to abandon PRESS selection and rely on a novel scheme of highly selective T1- and B1-insensitive outer-volume suppression in combination with slice-selective spin-echo acquisition for brain MRSI. Multiple cycles of overlapping suppression slabs are applied with flip angles optimized to account for tissue-dependent T1 relaxation times and band crossings. Broadband frequency modulated saturation pulses with polynomial phase-response are utilized in order to minimize chemical-shift displacement. Efficacy of the outer-volume suppression sequence was simulated and evaluated in vitro and in vivo. Brain MRSI localization at 3T was significantly improved and reliable suppression of short-range lipid contamination enabled, leading to substantial enhancement of spectral quality, particularly in cortical tissue. Hence, the new method holds potential to expand the applicability of high-field MRSI to the entire brain.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1002/mrm.21374
BibTex Citekey: HenningSSWPB2008
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 59 (1) Artikelnummer: - Start- / Endseite: 40 - 51 Identifikator: -