日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Optimized spectrally selective steady-state free precession sequences for cartilage imaging at ultra-high fields

Bieri, O., Mamisch TC, Trattnig S, Kraff O, Ladd, M., & Scheffler, K. (2008). Optimized spectrally selective steady-state free precession sequences for cartilage imaging at ultra-high fields. Magnetic Resonance Materials in Physics, Biology and Medicine, 21(1-2), 87-94. doi:10.1007/s10334-007-0092-0.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Bieri, O, 著者
Mamisch TC, Trattnig S, Kraff O, Ladd, ME, 著者
Scheffler, K1, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Object Fat suppressed 3D steady-state free precession (SSFP) sequences are of special interest in cartilage imaging due to their short repetition time in combination with high signal-to-noise ratio. At low-to-high fields (1.5–2.0 T), spectral spatial (spsp) radio frequency (RF) pulses perform superiorly over conventional saturation of the fat signal (FATSAT pulses). However, ultra-high fields (7.0 T and more) may offer alternative fat suppression techniques as a result of the increased chemical shift. Materials and methods Application of a single, frequency selective, RF pulse is compared to spsp excitation for water (or fat) selective imaging at 7.0 T. Results For SSFP, application of a single frequency selective RF pulse for selective water or fat excitation performs beneficially over the commonly applied spsp RF pulses. In addition to the overall improved fat suppression, the application of single RF pulses leads to decreased power depositions, still representing one of the major restrictions in the design and application of many pulse sequences at ultra-high fields. Conclusion The ease of applicability and implementation of single frequency selective RF pulses at ultra-high-fields might be of great benefit for a vast number of applications where fat suppression is desirable or fat–water separation is needed for quantification purposes.

資料詳細

表示:
非表示:
言語:
 日付: 2008-03
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://www.springerlink.com/content/u810p21742576m63/fulltext.pdf
DOI: 10.1007/s10334-007-0092-0
BibTex参照ID: BieriMTKLS2008
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 21 (1-2) 通巻号: - 開始・終了ページ: 87 - 94 識別子(ISBN, ISSN, DOIなど): -