  Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T

Henning, A., Schär M, Kollias SS, Boesiger, P., & Dydak, U. (2008). Quantitative magnetic resonance spectroscopy in the entire human cervical spinal cord and beyond at 3T. Magnetic Resonance in Medicine, 59(6), 1250–1258. doi:10.1002/mrm.21578.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Henning, A1, 著者           
Schär M, Kollias SS, Boesiger, P, 著者
Dydak, U, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Quantitative magnetic resonance spectroscopy (MRS) amends differential diagnostics of neurological pathology. However, due to technical challenges, it has rarely been applied to the spinal cord and has mainly been restricted to the very upper part of the cervical spine. In this work, an improved acquisition protocol is proposed that takes technical problems as strong magnetic field inhomogeneities, pulsatile flow of the cerebrospinal fluid (CSF), and small voxel size into account. For that purpose, inner-volume saturated point-resolved spectroscopy sequence (PRESS) localization, ECG triggering, and localized higher-order shimming and F0 determination, based on high-resolution cardiac-triggered static magnetic field B0 mapping, are combined. For inner-volume saturation a highly selective T1- and B1-insensitive outer-volume suppression (OVS) sequence based on broadband RF pulses with polynomial-phase response (PPR) is used. Validation is performed in healthy volunteers and patients with multiple sclerosis and intramedullary tumors. The applicability of spinal cord MRS is extended to the entire cervical spine. Spectral quality and its consistency are improved. In addition, high quality MRS patient data from a lesion that occluded the spinal canal in the thoracic spinal cord could be acquired. A quantitative analysis of patient spectra and spectra from healthy volunteers at different positions along the spinal cord underlines the diagnostic value of spinal cord MRS.

資料詳細

表示:
非表示:
言語:
 日付: 2008-06
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.21578/pdf
DOI: 10.1002/mrm.21578
BibTex参照ID: HenningSKBD2008
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 59 (6) 通巻号: - 開始・終了ページ: 1250–1258 識別子(ISBN, ISSN, DOIなど): -