  Theoretical and experimental comparison of different techniques for continuous arterial spin labelling

Pohmann, R., & Budde, J. (2008). Theoretical and experimental comparison of different techniques for continuous arterial spin labelling. Magnetic Resonance Materials in Physics, Biology and Medicine, 21(Supplement 1):, 205.

Item is

基本情報

表示: 非表示:
資料種別: 会議抄録

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Pohmann, R1, 2, 著者           
Budde, J1, 2, 著者           
所属:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: Continuous arterial spin labelling is the most sensitive
technique for perfusion measurements. Several schemes for tag and
control scans have been developped to overcome the technical and condeptual
problems of this technique. Here, four different approaches for tag and
control are simulated and compared experimentally.
Subjects and Methods: Four sequence variants are compared that differ
only in the way the tag or control pulses are applied: In CASL, separate tagging
coils at the neck label the inflowing blood with one long pulse [1]. In
ACASL, the tag is applied by the same coil used for imaging [2], but, due to
technical constraints, this pulse has to be interrupted at regular intervals.
For multi-slice acquisition (ms-ACASL) the control scan uses an oscillating
pulse to avoid nonsymmetric magnetization transfer effects [3]. In PCASL
[4], the tag is composed of a large number of short pulses and gradient
shapes, with the control scan modifying the puls phases as to be transparent
to the flowing spins. These four tagging techniques have been simulated and
implemented on a Siemens Trio with an EPI-readout. The simulations were
used to optimize the parameters of all sequences.
Results: Two volunteers were examined with each of the four techniques, as
well as with a standard FAIR sequence as representative of pulsed ASL. For
all CASL measurements, the tagging duration was 2 s; with a delay of 1s before
acquiring 7 slices (ss-ACASL: 1 slice). Only the center slice was used for
futher analysis. Figure 1 shows the perfusion images as generated with FSL
from the same slice in one volunteer acquired with all five sequences. Voxels
with a significant perfusion signal (Z = 3.7) are red. Sensitivity differences
between the sequences result in a different number of significant voxels.

資料詳細

表示:
非表示:
言語:
 日付: 2008-09
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-008-0125-3
BibTex参照ID: 5327
 学位: -

関連イベント

表示:
非表示:
イベント名: ESMRMB 2008 Congress: 25th Annual Meeting
開催地: Valencia, Spain
開始日・終了日: 2008-10-02 - 2008-10-04

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : No longer published by Elsevier
ページ: - 巻号: 21 (Supplement 1) 通巻号: 315 開始・終了ページ: 205 識別子(ISBN, ISSN, DOIなど): ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532