  In-vivo T1 and T2* tissue-relaxation rates of H2O17 at 16.4 Tesla

Wiesner, H., Balla, D., Pohmann, R., Chen, W., Ugurbil, K., & Uludag, K. (2008). In-vivo T1 and T2* tissue-relaxation rates of H2O17 at 16.4 Tesla. Poster presented at ISMRM Workshop on High-Field Systems and Applications 2008: "Whats special about 7T+?", Toronto, Canada.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
ISMRM2008-Workshop-Rome-Wiesner_[0].pdf (Zusammenfassung), 60KB
Name:
ISMRM2008-Workshop-Rome-Wiesner_[0].pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://www.ismrm.org/workshops/HF2008/index.htm (Inhaltsverzeichnis)
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Wiesner, HM1, 2, Autor           
Balla, DZ1, 2, Autor           
Pohmann, R1, 2, Autor           
Chen , W, Autor
Ugurbil, K, Autor
Uludag, K1, 2, Autor           
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The measurement of cerebral metabolic rate of oxygen (CMRO2) via direct NMR detection of the stable oxygen
isotope 17O is a promising tool to study alterations in brain activity and pathology. Due to the low natural
abundance of 0.037 H2O17, optimized acquisition parameters are crucial for 17O-weigthed MRI of metabolically
produced cerebral water. It has been suggested that signal-to-noise ratio increases almost quadratically with B0
due to field-independent quadrupolar interactions of 17O. Thus, in comparison to studies at lower field strengths the increased magnetization available at 16.4 T allows an enhanced spatial resolution and thus for the first time a tissue-specific determination of 17O relaxation.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2008-10
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: BibTex Citekey: 5698
 Art des Abschluß: -

Veranstaltung

einblenden:
ausblenden:
Titel: ISMRM Workshop on High-Field Systems and Applications 2008: "Whats special about 7T+?"
Veranstaltungsort: Toronto, Canada
Start-/Enddatum: 2008-10-15 - 2008-10-17

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle

einblenden: