  Shack-Hartmann wave front measurements in cortical tissue for deconvolution of large three-dimensional mosaic transmitted light brightfield micrographs

Oberlaender, M., Broser, P., Sakmann, B., & Hippler, S. (2009). Shack-Hartmann wave front measurements in cortical tissue for deconvolution of large three-dimensional mosaic transmitted light brightfield micrographs. Journal of Microscopy, 233(2), 275-289. doi:10.1111/j.1365-2818.2009.03118.x.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Oberlaender, M1, 著者           
Broser , PJ, 著者
Sakmann, B, 著者
Hippler, S, 著者
所属:
1External Organizations, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: We present a novel approach for deconvolution of 3D image stacks of cortical tissue taken by mosaic/optical-sectioning technology, using a transmitted light brightfield microscope. Mosaic/optical-sectioning offers the possibility of imaging large volumes (e.g. from cortical sections) on a millimetre scale at sub-micrometre resolution. However, a blurred contribution from out-of-focus light results in an image quality that usually prohibits 3D quantitative analysis. Such quantitative analysis is only possible after deblurring by deconvolution. The resulting image quality is strongly dependent on how accurate the point spread function used for deconvolution resembles the properties of the imaging system. Since direct measurement of the true point spread function is laborious and modelled point spread functions usually deviate from measured ones, we present a method of optimizing the microscope until it meets almost ideal imaging conditions. These conditions are validated by measuring the aberration function of the microscope and tissue using a Shack-Hartmann sensor. The analysis shows that cortical tissue from rat brains embedded in Mowiol and imaged by an oil-immersion objective can be regarded as having a homogeneous index of refraction. In addition, the amount of spherical aberration that is caused by the optics or the specimen is relatively low. Consequently the image formation is simplified to refraction between the embedding and immersion medium and to 3D diffraction at the finite entrance pupil of the objective. The resulting model point spread function is applied to the image stacks by linear or iterative deconvolution algorithms. For the presented dataset of large 3D images the linear approach proves to be superior. The linear deconvolution yields a significant improvement in signal-to-noise ratio and resolution. This novel approach allows a quantitative analysis of the cortical image stacks such as the reconstruction of biocytin-stained neuronal dendrites and axons.

資料詳細

表示:
非表示:
言語:
 日付: 2009-02
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1111/j.1365-2818.2009.03118.x
BibTex参照ID: OberlaenderBSH2009
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Microscopy
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Oxford : Blackwell Science
ページ: - 巻号: 233 (2) 通巻号: - 開始・終了ページ: 275 - 289 識別子(ISBN, ISSN, DOIなど): ISSN: 0022-2720
CoNE: https://pure.mpg.de/cone/journals/resource/954927663105_2