  Automatic slice positioning (ASP) for passive real-time tracking of interventional devices using projection-reconstruction imaging with echo-dephasing (PRIDE)

Patil, S., Bieri, O., & Scheffler, K. (2009). Automatic slice positioning (ASP) for passive real-time tracking of interventional devices using projection-reconstruction imaging with echo-dephasing (PRIDE). Magnetic Resonance in Medicine, 62(4), 935-942. doi:10.1002/mrm.22080.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Patil, S, 著者
Bieri, O, 著者
Scheffler, K1, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: A novel and fast approach for passive real-time tracking of interventional devices using paramagnetic markers, termed “projection-reconstruction imaging with echo-dephasing” (PRIDE) is presented. PRIDE is based on the acquisition of echo-dephased projections along all three physical axes. Dephasing is preferably set to 4π within each projection ensuring that background tissues do not contribute to signal formation and thus appear heavily suppressed. However, within the close vicinity of the paramagnetic marker, local gradient fields compensate for the intrinsic dephasing to form an echo. Successful localization of the paramagnetic marker with PRIDE is demonstrated in vitro and in vivo in the presence of different types of off-resonance (air/tissue interfaces, main magnetic field inhomogeneities, etc). In order to utilize the PRIDE sequence for vascular interventional applications, it was interleaved with balanced steady-state free precession (bSSFP) to provide positional updates to the imaged slice using a dedicated real-time feedback link. Active slice positioning (ASP) with PRIDE is demonstrated in vitro, requiring approximately 20 ms for the positional update to the imaging sequence, comparable to existing active tracking methods.

資料詳細

表示:
非表示:
言語:
 日付: 2009-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.22080/pdf
DOI: 10.1002/mrm.22080
BibTex参照ID: PatilBS2009
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 62 (4) 通巻号: - 開始・終了ページ: 935 - 942 識別子(ISBN, ISSN, DOIなど): -