  Cerebral Venous Thrombosis: Diagnostic Accuracy of Combined, Dynamic and Static, Contrast-Enhanced 4D MR Venography

Meckel, S., Reisinger C, Bremerich J, Damm D, Wolbers M, Engelter S, Scheffler, K., & Wetzel, S. (2010). Cerebral Venous Thrombosis: Diagnostic Accuracy of Combined, Dynamic and Static, Contrast-Enhanced 4D MR Venography. AJNR American Journal of Neuroradiology, 31(3), 527-535. doi:10.3174/ajnr.A1869.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Meckel, S, Autor
Reisinger C, Bremerich J, Damm D, Wolbers M, Engelter S, Scheffler, K1, Autor           
Wetzel, SG, Autor
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: BACKGROUND AND PURPOSE: MR including MRV is an established method to diagnose CVT. However, it remains unsettled which MR imaging modalities offer the highest diagnostic accuracy. We evaluated the accuracy of a combined, dynamic (1.5 seconds per dataset) and static (voxel size, 1.1 x 0.9 x 1.5 mm), contrast-enhanced MRV method (combo-4D MRV) relative to other established MR/MRV modalities. MATERIALS AND METHODS: A total of 39 patients with CVT (n = 20) and control subjects (n = 19) underwent combo-4D MRV, 2D TOF MRV, GRE imaging, and T2W imaging. For these modalities, diagnostic accuracy (ROCs) for CVT affecting 53 out of 234 predefined venous segments was determined. Sensitivity and specificity were separately calculated for different stages of CVT (acute/subacute/chronic). RESULTS: Combo-4D MRV showed the highest accuracy (AUC, 0.99 [95 CI, 0.97-1.0]; sensitivity, 97 [84-100]) for thrombosed dural sinuses. For all thrombosed segments including cortical veins, its sensitivity was best (76 [64-84]; AUC, 0.92 [0.88-0.96]), followed by TOF MRV (72 [59-81]; AUC, 0.93 [0.88-0.97]). Even for chronic CVT, it showed a relatively high sensitivity of 67 (30-90). For thrombosed cortical veins alone, GRE images achieved the highest sensitivity (66 [46-81]; AUC, 0.88 [0.78-0.97]). Specificities of all modalities ranged from 96 to 99. CONCLUSIONS: Combo-4D MRV showed an excellent accuracy for the diagnosis of dural sinus thrombosis. The analysis of dynamic patterns of contrast enhancement in dural sinuses appeared useful to identify chronic thrombosis. To diagnose thrombosed cortical veins, GRE images should primarily be analyzed.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2010-03
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://www.ajnr.org/content/31/3/527.long
DOI: 10.3174/ajnr.A1869
BibTex Citekey: MeckelRBDWESW2010
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: AJNR American Journal of Neuroradiology
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 31 (3) Artikelnummer: - Start- / Endseite: 527 - 535 Identifikator: -