日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Signal characteristics of focal bone marrow lesions in patients with multiple myeloma using whole body T1w-TSE, T2w-STIR and diffusion-weighted imaging with background suppression

Sommer, G., Klarhöfer M, Lenz C, Scheffler, K., Bongartz, G., & Winter, L. (2011). Signal characteristics of focal bone marrow lesions in patients with multiple myeloma using whole body T1w-TSE, T2w-STIR and diffusion-weighted imaging with background suppression. European Radiology, 21(4), 857-862. doi:10.1007/s00330-010-1950-0.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Sommer, G, 著者
Klarhöfer M, Lenz C, Scheffler, K1, 著者           
Bongartz, G, 著者
Winter, L, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Objective This study analyses the diagnostic potential of Diffusion-Weighted Imaging with Background Suppression (DWIBS) in the detection of focal bone marrow lesions from multiple myeloma. The signal and contrast properties of DWIBS are evaluated in correlation with the serum concentration of M-component (MC) and compared with established T1- and T2-weighted sequences. Methods Data from 103 consecutive studies in 81 patients are analysed retrospectively. Signal intensities and apparent Diffusion Coefficients (ADC) of 79 focal lesions in the lumbar spine or pelvis of 38 patients are determined and contrast-to-noise-ratio (CNR) is calculated. Data from patients with low (<20 g/L) and high (>20 g/dL) MC are evaluated separately. Results Signal intensities of focal myeloma lesions on T2w-STIR vary significantly depending on the MC, which leads to a loss in CNR in patients with high MC. No signal variation is observed for T1w-TSE and DWIBS. The CNR values provided by DWIBS in patients with high MC are slightly higher than those of T2w-STIR. ADC values in patients with low MC are significantly higher than in patients with high MC. Conclusion Whole-body DWIBS has the potential to improve the conspicuity of focal myeloma lesions and provides additional biological information by ADC quantification.

資料詳細

表示:
非表示:
言語:
 日付: 2011-04
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://www.springerlink.com/content/a8856471w160238h/fulltext.pdf
DOI: 10.1007/s00330-010-1950-0
BibTex参照ID: SommerKLSBW2011
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: European Radiology
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 21 (4) 通巻号: - 開始・終了ページ: 857 - 862 識別子(ISBN, ISSN, DOIなど): -