  A 15-Channel receive array and 16 channel detunable transmit coil for human brain imaging at 9.4T

Shajan, G., Hoffmann, J., & Pohmann, R. (2011). A 15-Channel receive array and 16 channel detunable transmit coil for human brain imaging at 9.4T. Poster presented at 19th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2011), Montréal, Canada.

Item is

Files

show Files
hide Files
:
ISMRM-2011-3825.pdf (Abstract), 457KB
Name:
ISMRM-2011-3825.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show
hide
Locator:
https://www.ismrm.org/11/ (Table of contents)
Description:
-
OA-Status:

Creators

show
hide
 Creators:
Shajan, G1, 2, Author           
Hoffmann, J1, 2, Author           
Pohmann, R1, 2, Author           
Affiliations:
1Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_2528700              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

Content

show
hide
Free keywords: -
 Abstract: The radio frequency (RF) magnetic field (B1) distribution becomes more complex in MR experiments employing higher static magnetic field (B0) due to shorter wavelength in tissue. The B1 + inhomogeneities from a predefined volume of interest is reduced by influencing the amplitude and phase of the transmit current on a transceiver array coil [1, 2]. Significant gains in SNR was achieved at 7T using 32 channel receive arrays assembled on close fitting formers [3, 4]. In this study, we combine the benefits of these two methods for human brain MRI at 9.4T (400MHz).
Our imaging setup consists of a 15-element receive array together with a 16-element actively detunable transmit array and hence the additional flexibility to employ RF shimming methods.

Details

show
hide
Language(s):
 Dates: 2011-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: BibTex Citekey: GunamonyHP2011
 Degree: -

Event

show
hide
Title: 19th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2011)
Place of Event: Montréal, Canada
Start-/End Date: 2011-05-07 - 2011-05-13

Legal Case

show

Project information

show

Source 1

show
hide
Title: 19th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2011)
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: 3825 Identifier: -