  Multislice 2D spin echo imaging using adapted readout gradients for compensation of BO inhomogeneities and gradient nonlinearities

Blumhagen, J., Ladebeck, R., Fenchel, M., & Scheffler, K. (2011). Multislice 2D spin echo imaging using adapted readout gradients for compensation of BO inhomogeneities and gradient nonlinearities. Poster presented at 28th Annual Scientific Meeting ESMRMB 2011, Leipzig, Germany.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

作成者

表示:
非表示:
 作成者:
Blumhagen, JO, 著者
Ladebeck, R, 著者
Fenchel, M, 著者
Scheffler, K1, 2, 著者           
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Max Planck Institute for Biological Cybernetics, Max Planck Society, Spemannstrasse 38, 72076 Tübingen, DE, ou_1497794              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: In whole-body MR/PET, the limitation of an MR-based axial field-of-view (FoV) due to B0 inhomogeneities and gradient nonlinearities [1,2] may cause a truncation of the MR data and has therefore potential impact on the attenuation correction [3]. Furthermore, a large FoV may also be relevant in MR-based interventional applications, e.g. radiotherapy and biopsy. Recently, the feasibility of an axial extension of the MR-based FoV using a gradient field that compensates the B0 inhomogeneities has been shown [4]. However, the optimal gradient strength is space-dependent and therefore does not achieve optimal distortion reduction in all slices. In this work we developed a multislice 2D spin-echo-based sequence that calculates and adapts the readout (RO) gradient for each slice position automatically and offers an extended FoV in multiple slices during one single scan. Subjects and Methods: Distortions due to B0 inhomogeneities and gradient nonlinearities in 2DFT SE frequency encoding can be reduced by using an adapted space-dependent readout gradient: GRO (x,y,z) = - δB0(x,y,z) / c(x,y,z), where δB0 is the B0 inhomogeneity and c is the relative error in the gradient field. Field deviations in the main magnetic field and the gradient field were quantified as described in [4]. A multislice 2D spin-echo-based sequence was developed to calculate and adapt the optimal RO gradient strength and polarity for each slice position automatically (Fig. 1).

資料詳細

表示:
非表示:
言語:
 日付: 2011-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1007/s10334-011-0268-5
BibTex参照ID: BlumhagenLFS2011
 学位: -

関連イベント

表示:
非表示:
イベント名: 28th Annual Scientific Meeting ESMRMB 2011
開催地: Leipzig, Germany
開始日・終了日: 2011-10-06 - 2011-10-08

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance Materials in Physics, Biology and Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : No longer published by Elsevier
ページ: - 巻号: 24 (Supplement 1) 通巻号: - 開始・終了ページ: 424 識別子(ISBN, ISSN, DOIなど): ISSN: 0968-5243
CoNE: https://pure.mpg.de/cone/journals/resource/954926245532