  Evaluation and Optimization of MR-Based Attenuation Correction Methods in Combined Brain PET/MR

Mantlik, F., Hofmann, M., Bezrukov, I., Schmidt H, Kolb A, Beyer T, Reimold M, Schölkopf, B., & Pichler, B. (2011). Evaluation and Optimization of MR-Based Attenuation Correction Methods in Combined Brain PET/MR. Poster presented at 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011), Valencia, Spain.

Item is

基本情報

表示: 非表示:
資料種別: ポスター

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Mantlik, F1, 著者           
Hofmann, M1, 著者           
Bezrukov, I1, 著者           
Schmidt H, Kolb A, Beyer T, Reimold M, Schölkopf, B1, 著者           
Pichler, BJ, 著者
所属:
1Department Empirical Inference, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497795              

内容説明

表示:
非表示:
キーワード: -
 要旨: Combined PET/MR provides simultaneous molecular and functional information in an anatomical context with unique soft tissue contrast. However, PET/MR does not support direct derivation of attenuation maps of objects and tissues within the measured PET field-of-view. Valid attenuation maps are required for quantitative PET imaging, specifically for scientific brain studies. Therefore, several methods have been proposed for MR-based attenuation correction (MR-AC). Last year, we performed an evaluation of different MR-AC methods, including simple MR thresholding, atlas- and machine learning-based MR-AC. CT-based AC served as gold standard reference. RoIs from 2 anatomic brain atlases with different levels of detail were used for evaluation of correction accuracy. We now extend our evaluation of different MR-AC methods by using an enlarged dataset of 23 patients from the integrated BrainPET/MR (Siemens Healthcare). Further, we analyze options for improving the MR-AC performance in terms of speed and accuracy. Finally, we assess the impact of ignoring BrainPET positioning aids during the course of MR-AC. This extended study confirms the overall prediction accuracy evaluation results of the first evaluation in a larger patient population. Removing datasets affected by metal artifacts from the Atlas-Patch database helped to improve prediction accuracy, although the size of the database was reduced by one half. Significant improvement in prediction speed can be gained at a cost of only slightly reduced accuracy, while further optimizations are still possible.

資料詳細

表示:
非表示:
言語:
 日付: 2011-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://www.nss-mic.org/2011/program/ListProgramDB.asp?session=MIC18.M
BibTex参照ID: MantlikHBSKBRSP2011
 学位: -

関連イベント

表示:
非表示:
イベント名: 2011 IEEE Nuclear Science Symposium, Medical Imaging Conference (NSS-MIC 2011)
開催地: Valencia, Spain
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物

表示: