  Use of respiratory biofeedback and CLAWS for increased navigator efficiency for imaging the thoracic aorta

Jhooti, P., Haas T, Kawel N, Bremerich J, Keegan, J., & Scheffler, K. (2011). Use of respiratory biofeedback and CLAWS for increased navigator efficiency for imaging the thoracic aorta. Magnetic Resonance in Medicine, 66(6), 1666–1673. doi:10.1002/mrm.22945.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Jhooti, P, Autor
Haas T, Kawel N, Bremerich J, Keegan, J, Autor
Scheffler, K1, Autor           
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: A novel technique to guide a subjects' breathing pattern using a respiratory biofeedback (rBF) “game” to improve respiratory efficiency is presented. The continuously adaptive windowing strategy, a fully automatic and highly efficient free-breathing navigator gated technique, is used to acquire the data as it ensures that all potential navigator acceptance windows are possible. This enables the rBF to be fully adaptable to a subject's respiratory pattern. Images of the thoracic aorta acquired using balanced steady-state free precession with continuously adaptive windowing strategy respiratory motion control, with and without rBF, were compared in 10 healthy subjects. Total scan time was reduced by using rBF. The mean scan time was reduced from 7 min 44 s (463 cardiac cycles, ±127cc) without rBF to 5 min 43 s (380 cardiac cycles, ±118cc) with the use of rBF (P < 0.05). Respiratory efficiency was increased from 45 without rBF to 56 with rBF (P < 0.01). Image quality was the same for both techniques (P = ns). In conclusion, rBF significantly improved respiratory efficiency and reduced acquisition duration without affecting image quality.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2011-12
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: URI: http://onlinelibrary.wiley.com/doi/10.1002/mrm.22945/pdf
DOI: 10.1002/mrm.22945
BibTex Citekey: JhootiHKBKS2011
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 66 (6) Artikelnummer: - Start- / Endseite: 1666–1673 Identifikator: -