日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Optically transmitted and inductively coupled electric reference to access in vivo concentrations for quantitative proton-decoupled 13C magnetic resonance spectroscopy

Chen, X., Pavan, M., Heinzer-Schweizer, S., Boesiger, P., & Henning, A. (2012). Optically transmitted and inductively coupled electric reference to access in vivo concentrations for quantitative proton-decoupled 13C magnetic resonance spectroscopy. Magnetic Resonance in Medicine, 67(1), 1-7. doi:10.1002/mrm.23110.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Chen, X, 著者
Pavan, M, 著者
Heinzer-Schweizer, S, 著者
Boesiger, P, 著者
Henning, A1, 著者           
所属:
1Institute for Biomedical Engineering, University and ETH Zurich, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: This report describes our efforts on quantification of tissue metabolite concentrations in mM by nuclear Overhauser enhanced and proton decoupled 13C magnetic resonance spectroscopy and the Electric Reference To access In vivo Concentrations (ERETIC) method. Previous work showed that a calibrated synthetic magnetic resonance spectroscopy-like signal transmitted through an optical fiber and inductively coupled into a transmit/receive coil represents a reliable reference standard for in vivo 1H magnetic resonance spectroscopy quantification on a clinical platform. In this work, we introduce a related implementation that enables simultaneous proton decoupling and ERETIC-based metabolite quantification and hence extends the applicability of the ERETIC method to nuclear Overhauser enhanced and proton decoupled in vivo 13C magnetic resonance spectroscopy. In addition, ERETIC signal stability under the influence of simultaneous proton decoupling is investigated. The proposed quantification method was cross-validated against internal and external reference standards on human skeletal muscle. The ERETIC signal intensity stability was 100.65 ± 4.18 over 3 months including measurements with and without proton decoupling. Glycogen and unsaturated fatty acid concentrations measured with the ERETIC method were in excellent agreement with internal creatine and external phantom reference methods, showing a difference of 1.85 ± 1.21 for glycogen and 1.84 ± 1.00 for unsaturated fatty acid between ERETIC and creatine-based quantification, whereas the deviations between external reference and creatine-based quantification are 6.95 ± 9.52 and 3.19 ± 2.60, respectively.

資料詳細

表示:
非表示:
言語:
 日付: 2012-01
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.23110
BibTex参照ID: ChenPHBH2012
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 67 (1) 通巻号: - 開始・終了ページ: 1 - 7 識別子(ISBN, ISSN, DOIなど): -