日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Non-water-suppressed proton MR spectroscopy improves spectral quality in the human spinal cord

Hock, A., MacMillan, E., Fuchs, A., Kreis, R., Boesiger, P., Kollias, S., & Henning, A. (2013). Non-water-suppressed proton MR spectroscopy improves spectral quality in the human spinal cord. Magnetic Resonance in Medicine, 69(5), 1253-1260. doi:10.1002/mrm.24387.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Hock, A, 著者
MacMillan, EL, 著者
Fuchs, A, 著者
Kreis, R, 著者
Boesiger, P, 著者
Kollias, SS, 著者
Henning, A1, 著者           
所属:
1Departament of Information Technology and Electrical Engineering, University and ETH Zurich, , ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: Magnetic resonance spectroscopy enables insight into the chemical composition of spinal cord tissue. However, spinal cord magnetic resonance spectroscopy has rarely been applied in clinical work due to technical challenges, including strong susceptibility changes in the region and the small cord diameter, which distort the lineshape and limit the attainable signal to noise ratio. Hence, extensive signal averaging is required, which increases the likelihood of static magnetic field changes caused by subject motion (respiration, swallowing), cord motion, and scanner-induced frequency drift. To avoid incoherent signal averaging, it would be ideal to perform frequency alignment of individual free induction decays before averaging. Unfortunately, this is not possible due to the low signal to noise ratio of the metabolite peaks. In this article, frequency alignment of individual free induction decays is demonstrated to improve spectral quality by using the high signal to noise ratio water peak from non-water-suppressed proton magnetic resonance spectroscopy via the metabolite cycling technique. Electrocardiography (ECG)-triggered point resolved spectroscopy (PRESS) localization was used for data acquisition with metabolite cycling or water suppression for comparison. A significant improvement in the signal to noise ratio and decrease of the Cramér Rao lower bounds of all metabolites is attained by using metabolite cycling together with frequency alignment, as compared to water-suppressed spectra, in 13 healthy volunteers.

資料詳細

表示:
非表示:
言語:
 日付: 2012-062013-05
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/mrm.24387
BibTex参照ID: HockMFKBKH2012
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 69 (5) 通巻号: - 開始・終了ページ: 1253 - 1260 識別子(ISBN, ISSN, DOIなど): -