日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  In-vivo Proton Chemical Shift Imaging at 9.4 T: initial results

Chadzynski, G., Shajan, G., Kolb R, Pohmann, R., Klose, U., & Scheffler, K. (2012). In-vivo Proton Chemical Shift Imaging at 9.4 T: initial results. Talk presented at 29th Annual Scientific Meeting ESMRMB 2012. Lisboa, Portugal.

Item is

基本情報

表示: 非表示:
資料種別: 講演

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Chadzynski, GI1, 著者           
Shajan, G1, 著者           
Kolb R, Pohmann, R1, 著者           
Klose, U, 著者
Scheffler, K, 著者
所属:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

内容説明

表示:
非表示:
キーワード: -
 要旨: Purpose/Introduction: Despite of the known difficulties (longer T1 and shorter T2 relaxation times, higher SAR and stronger B0 and B1 inhomogeneities), the feasibility of in-vivo 1H MRS at a field strength of 9.4 T has been recently demonstrated in [1]. Since the main advantage of CSI over SVS is providing the additional information about the spatial distribution of metabolites, the aim of this study was to examine the feasibility of CSI in the human brain at a field strength of 9.4 T. Subjects and Methods: In-vivo measurements (3 healthy volunteers) were performed on a whole body 9.4 T MR scanner (Siemens, Erlangen, Germany). CSI data were collected with a custom built 8 channel transmit coil combined with a 24 channel receiving helmet. Spectra were acquired with a modified STEAM sequence (TR=2000 ms, TE=20 ms, TM=11 ms, spectral bandwidth: 4000 Hz, voxel size: 10 mm3 isotropic). The main modification of the pulse sequence consisted in replacing the 90° h-sinc RF pulses with 90° hermite pulses, which allowed keeping the reference voltage below the hardware limitations and minimized the RF power deposition. Raw spectra were quantified with LCModel, version 6.2-2B [2] using a basis set (17 metabolites) simulated in VeSPA software (http://scion.duhs.duke.edu/vespa/). Results: It can be seen that all the spectra are decent in terms of SNR and spectral resolution (Fig. 1). Especially in two regions; between ~2.4 and ~2.6 and ~1.9 and ~2.3 ppm: is the overlap between the resonances of Gln, Glu, NAA and NAAG reduced. Quantification with LCModel software (Fig. 2) confirmed those observations. Peaks of NAA, NAAG and Glu were assigned with Cramer-Rao lower bounds (CRLB) below 13. Moreover, 13 metabolites of the 17 included in the basis set were quantified with CLRB below 20. Comparable results have been obtained for the other volunteers. Discussion/Conclusion: It has been demonstrated that 1H MRSI at a field strength of 9.4 T is feasible. All acquired spectra demonstrated good agreement in terms of spectral quality with the results published previously [1, 3]. In conclusion, the enhanced sensitivity in the detection of metabolite resonances with CSI at ultra-high fields combined with the additional information about spatial distribution of the metabolites can provide new insights to the assessment of various pathologies.

資料詳細

表示:
非表示:
言語:
 日付: 2012-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): URI: http://www.springerlink.com/content/c040111527158u51/
DOI: 10.1007/s10334-012-0323-x
BibTex参照ID: ChadzynskiSKPKS2012
 学位: -

関連イベント

表示:
非表示:
イベント名: 29th Annual Scientific Meeting ESMRMB 2012
開催地: Lisboa, Portugal
開始日・終了日: -

訴訟

表示:

Project information

表示:

出版物

表示: