日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Linear two-step gradient counter-current chromatography : analysis based on a recursive solution of an equilibrium stage model

Beltscheva, D., Hugo, P., & Seidel-Morgenstern, A. (2003). Linear two-step gradient counter-current chromatography: analysis based on a recursive solution of an equilibrium stage model. Journal of Chromatography A, 989(1), 31-45. doi:10.1016/S0021-9673(02)01962-3.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : J. Chromatogr. A

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Beltscheva, D.1, 著者
Hugo, P.1, 著者
Seidel-Morgenstern, A.2, 3, 著者           
所属:
1Tech Univ Berlin, Inst Tech Chem, Berlin, Germany, ou_persistent22              
2Physical and Chemical Foundations of Process Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738150              
3Otto-von-Guericke-Universität Magdeburg, External Organizations, ou_1738156              

内容説明

表示:
非表示:
キーワード: counter-current chromatography; gradient elution; adsorption isotherms; equilibrium stage model; mathematical modeling; preparative chromatography
 要旨: The implementation of gradients in continuously operated chromatographic counter-current processes has recently attracted considerable interest as a method to improve the performance of this effective separation method. If liquid mobile phases are applied it is advantageous to set the solvent strength in the desorbent stream higher than that in the feed stream. As a consequence, the components to be separated are more retained in the adsorption zones and more easily eluted in the desorption zones. Due to the additional degrees of freedom the design and the optimization of such a two-step gradient counter-current process is difficult. In this paper a steady state equilibrium stage model is used to simulate the process under linear conditions. A simple solution of the underlying model equations is presented capable to describe efficiently the unit for large stage numbers typically encountered in chromatographic columns. Due to the rapidity of the algorithm developed a broad range of operating conditions can be evaluated systematically for different types of gradients. The impact of (a) the functional dependence of the adsorption equilibrium constants on the solvent composition, (b) the number of equilibrium stages and (c) the specification of purity requirements is illustrated and discussed based on results of parametric calculations. The results achieved emphasize the potential of two-step gradient counter-current chromatography. copyright 2003 Elsevier B.V. All rights reserved. [accessed 2013 November 28th]

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2003
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 13816
DOI: 10.1016/S0021-9673(02)01962-3
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Chromatography A
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : Elsevier
ページ: - 巻号: 989 (1) 通巻号: - 開始・終了ページ: 31 - 45 識別子(ISBN, ISSN, DOIなど): ISSN: 0021-9673
CoNE: https://pure.mpg.de/cone/journals/resource/954925527837_1