日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Flow cytometric monitoring of influenza A virus infection in MDCK cells during vaccine production

Schulze-Horsel, J., Genzel, Y., & Reichl, U. (2008). Flow cytometric monitoring of influenza A virus infection in MDCK cells during vaccine production. BMC Biotechnology, 8, 45. doi:10.1186/1472-6750-8-45.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
eDoc_327772_2008.pdf (出版社版), 460KB
ファイルのパーマリンク:
https://hdl.handle.net/11858/00-001M-0000-0013-95FE-8
ファイル名:
eDoc_327772_2008.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
© 2008 Schulze-Horsel et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Schulze-Horsel, J.1, 著者           
Genzel, Y.1, 著者           
Reichl, U.1, 2, 著者           
所属:
1Bioprocess Engineering, Max Planck Institute for Dynamics of Complex Technical Systems, Max Planck Society, ou_1738140              
2Otto-von-Guericke-Universität Magdeburg, ou_1738156              

内容説明

表示:
非表示:
キーワード: -
 要旨: Background In cell culture-based influenza vaccine production the monitoring of virus titres and cell physiology during infection is of great importance for process characterisation and optimisation. While conventional virus quantification methods give only virus titres in the culture broth, data obtained by fluorescence labelling of intracellular virus proteins provide additional information on infection dynamics. Flow cytometry represents a valuable tool to investigate the influences of cultivation conditions and process variations on virus replication and virus yields. Results In this study, fluorescein-labelled monoclonal antibodies against influenza A virus matrix protein 1 and nucleoprotein were used for monitoring the infection status of adherent Madin-Darby canine kidney cells from bioreactor samples. Specific binding of monoclonal antibodies was shown for influenza A virus strains of different subtypes (H1N1, H1N5, H3N8) and host specificity (human, equine, swine). At high multiplicity of infection in a bioreactor, the onset of influenza virus replication was detected at about 2 to 4 h post infection by immunocytometry. In contrast, a significant increase in titre by hemagglutination assay was detected at the earliest 4 to 6 h post infection. In addition to the quantification of the infected cell fraction, influenza A virus nucleoprotein and matrix protein copy numbers in cells could be estimated from the measured fluorescence intensities. The fluorescence intensity threshold for infected cell quantification was equivalent to 76 000 nucleoprotein and matrix protein 1 copies per cell, which corresponds to 19 virions at the most. Conclusions It is shown that immunocytometry is a sensitive and robust method for the monitoring of viral infection and the quantification of virus protein content in fixed cells from bioreactor samples. Therefore, it is a valuable addition to other detection methods of influenza virus infection such as immunotitration and RNA hybridisation. Thousands of individual cells are measured per sample. Thus, the presented method is believed to be quite independent of the concentration of infected cells (multiplicity of infection and total cell concentration) in bioreactors. This allows to perform detailed studies on factors relevant for optimization of virus yields in cell cultures. The method could also be used for process characterisation and investigations concerning reproducibility in vaccine manufacturing. © 2008 Schulze-Horsel et al; licensee BioMed Central Ltd. [accessed June 6, 2008]

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2008
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 327772
その他: 13/08
DOI: 10.1186/1472-6750-8-45
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: BMC Biotechnology
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: BioMed Central
ページ: - 巻号: 8 通巻号: - 開始・終了ページ: 45 識別子(ISBN, ISSN, DOIなど): ISSN: 1472-6750
CoNE: https://pure.mpg.de/cone/journals/resource/111000136906066