Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Real-time MRI as a new technique for the funtional assesment of the temporomandibular joint.

Kling, O., Rödiger, M., Zhang, S., Frahm, J., & Gersdorff, N. (2013). Real-time MRI as a new technique for the funtional assesment of the temporomandibular joint. Journal of Craniomandibular Function, 5(1), 9-18.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Kling, O., Autor
Rödiger, M., Autor
Zhang, S.1, Autor           
Frahm, J.1, Autor           
Gersdorff, N., Autor
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: TMD, real-time MRI, RDC/TMD, sensitivity, specificity
 Zusammenfassung: For the diagnostics of the temporomandibular joint, the dental treatment provider has a series of procedures at his/ her disposal. In addition to the recording of the case history and the clinical functional analysis, magnetic resonance imaging (MRI) plays an important part as the so-called "gold standard". To this purpose, both the osseous and the connective tissue structures are depicted in high resolution. For technical reasons, however, it was only possible to produce static images to date, although the dynamic examination of the temporomandibular joint and the use of corresponding imaging procedures during splint therapy are certainly considered advantageous. The technique presented here makes it possible to record a real-time MRI movies of arbitrary length with a frame rate of 3 images per second. This means that a dynamic depiction of the temporomandibular joint function is possible. In this article, 30 test subjects were examined clinically according to the RDC/TMD, and the temporomandibular joint movement recorded using real-time magnetic resonance imaging. The goal of this task was the comparison of the clinical examination results with those of real-time MRI in order to ascertain the potential additional value of real-time MRI with regard to diagnostic information. This resulted in Cohen's kappa values of 0.88 to 0.849. In the second examination, the study results showed a 99.95% rate of agreement. Furthermore, this resulted in a sensitivity value of 0.67 and specificity values ranging between 0.88 and 0.98. On the one hand, the results reflect the high image quality and good anatomical accessibility, and on the other hand seem to offer more valuable information for diagnostic purposes. The insights gained give the first indication that real-time MRI appears to be superior to static MRI.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2013-03-152013
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: -
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Craniomandibular Function
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 5 (1) Artikelnummer: - Start- / Endseite: 9 - 18 Identifikator: -