  Improved isotope ratio measurement performance in liquid chromatography/isotope ratio mass spectrometry by removing excess oxygen

Hettmann, E., Brand, W. A., & Gleixner, G. (2007). Improved isotope ratio measurement performance in liquid chromatography/isotope ratio mass spectrometry by removing excess oxygen. Rapid Communications in Mass Spectrometry, 21(24), 4135-4141. doi:10.1002/rcm.3304.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
BGC1236.pdf (出版社版), 233KB
 
ファイルのパーマリンク:
-
ファイル名:
BGC1236.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (Max Planck Institute for Biogeochemistry, MJBK; )
MIMEタイプ / チェックサム:
application/octet-stream
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Hettmann, E.1, 著者           
Brand, W. A.2, 著者           
Gleixner, G.1, 著者           
所属:
1Molecular Biogeochemistry Group, Dr. G. Gleixner, Department Biogeochemical Processes, Prof. E.-D. Schulze, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497773              
2Service Facility Stable Isotope/Gas Analytics, Dr. W. A. Brand, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497772              

内容説明

表示:
非表示:
キーワード: -
 要旨: A low dead volume oxygen scrubbing system was introduced in a commercially available liquid chromatography/isotope ratio mass spectrometry (LC/IRMS) interface to enhance the analytical capability of the system. In the LC/IRMS interface carbon from organic samples is converted into CO2 inside the mobile phase by wet chemical oxidation using peroxodisulfate (Na2S2O8). After passing the hot reaction zone, surplus oxygen (O-2) remains dissolved in the liquid phase. Both CO2 and O-2 diffuse through a transfer membrane into the helium carrier and are transferred to the mass spectrometer. The presence of O-2 in the ion source may have detrimental effects on measurement accuracy and precision as well as on filament lifetime. As a remedy, a new on-line O-2-removing device has been incorporated into the system. The new O-2 scrubber consists of two parallel hot copper reduction reactors (0.8 mm i.d., active length 120mm) and a switch-over valve between them. One reactor is regenerated using He/H-2 while the other is actively scavenging O-2 from the gas stream. The capacity of each reduction reactor, expressed as usage time, is between 40 and 50 min. This is sufficient for a single LC run for sugars and organic acids. A further increase of the reduction capacity is accompanied by a peak broadening of about 100%. After switching to a freshly reduced reactor the oxygen background and the delta C-13 values of the reference gas need up to 500 s to stabilize. For repeated injections the delta C-13 values of sucrose remain constant (+/- 0.1 parts per thousand) for about 3000 s. The long-term stability for measurements of sucrose was 0.11 parts per thousand without the reduction oven and improved slightly to 0.08 parts per thousand with the reduction oven. The filament lifetime improved by more than 600%, thereby improving the long-term system stability and analytical efficiency. In addition the costs per analysis were reduced considerably.

資料詳細

表示:
非表示:
言語:
 日付: 2007
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1002/rcm.3304
その他: BGC1236
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Rapid Communications in Mass Spectrometry
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: New York, NY : John Wiley & Sons
ページ: - 巻号: 21 (24) 通巻号: - 開始・終了ページ: 4135 - 4141 識別子(ISBN, ISSN, DOIなど): CoNE: https://pure.mpg.de/cone/journals/resource/954925574961
ISSN: 0951-4198