日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Ion-chromatographic determination of low concentrations of nitrate in solutions of high salinity

Raessler, M., & Hilke, I. (2006). Ion-chromatographic determination of low concentrations of nitrate in solutions of high salinity. Microchimica Acta, 154(1-2), 27-29.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
BGC0887.pdf (出版社版), 50KB
 
ファイルのパーマリンク:
-
ファイル名:
BGC0887.pdf
説明:
-
OA-Status:
閲覧制限:
制限付き (Max Planck Institute for Biogeochemistry, MJBK; )
MIMEタイプ / チェックサム:
application/octet-stream
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Raessler, M.1, 著者           
Hilke, I.2, 著者           
所属:
1Service Facility Spectrometry, Dr. M. Raessler, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497771              
2Service Facility Routine Measurements and Analysis (RoMA), I. Hilke, Max Planck Institute for Biogeochemistry, Max Planck Society, ou_1497770              

内容説明

表示:
非表示:
キーワード: Nitrate High salinity Bromide interference Ion chromatography Anions
 要旨: The determination of low concentrations of inorganic anions in water samples of high salinity is one of the most difficult tasks in analytical chemistry. There is, however, an increasing demand for the exact and reliable determination of nutrients even at very low concentration levels in environmental samples of complex composition. We therefore present the development, quality control and application of an easy and rugged method that makes possible the determination of trace amounts of nitrate in solutions with high concentrations of chloride (> 30 000 mu gL(-1)) and a hundred-fold excess of bromide ions, based on ion chromatography with UV detection at lambda = 210 nm. While chloride ions show no absorbance at this wavelength, a bromide concentration > 1500 mu gL(-1) severely interferes with nitrate determination at the trace level. On the contrary, at nitrate concentrations of > 500 mu gL(-1), this bromide interference becomes negligible. Consequently, to overcome the impact of bromide on the trace level determination of nitrate, all samples are spiked with a definite volume of a nitrate standard solution to obtain an overall nitrate concentration of > 500 mu gL(-1) which allows the exact and reliable determination of nitrate concentrations down to 25 mu gL(-1). We will report the successful application of the method to samples of high salinity. [References: 6]

資料詳細

表示:
非表示:
言語:
 日付: 2006
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): その他: BGC0887
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Microchimica Acta
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Wien : Springer-Verlag Wien
ページ: - 巻号: 154 (1-2) 通巻号: - 開始・終了ページ: 27 - 29 識別子(ISBN, ISSN, DOIなど): CoNE: https://pure.mpg.de/cone/journals/resource/110978977736125_1
ISSN: 0026-3672