English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Refractive anomalies and visual activation in functional magnetic resonance imaging (fMRI): A versatile and low-cost MR- compatible device to correct a potential confound

Elbel, G., Kaufmann, C., Schaefers, S., Buser, A., & Auer, D. (2002). Refractive anomalies and visual activation in functional magnetic resonance imaging (fMRI): A versatile and low-cost MR- compatible device to correct a potential confound. Journal of Magnetic Resonance Imaging, 15(1), 101-107.

Item is

Basic

show hide
Genre: Journal Article
Alternative Title : J. Magn. Reson. Imaging

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Elbel, GK1, Author
Kaufmann, C1, Author
Schaefers, S1, Author
Buser, A1, Author
Auer, DP1, Author
Affiliations:
1Max Planck Institute of Psychiatry, Max Planck Society, ou_1607137              

Content

show
hide
Free keywords: refractive error; refractive correction; visual stimulation; fMRI; optic blur; myopia; presbyopia
 Abstract: Purpose: To develop a magnetic resonance (MR)-compatible, versatile, easy-to-use, and low-cost device for refractive correction. Materials and Methods: We retrospectively evaluated the application and practicability of the refractive correction in 110 subjects who had participated in various functional MR imaging (fMRI) studies with complex visual stimulation paradigms since the introduction of the MR-compatible lens frame at our site. The subjects consisted of 31 patients with Parkinson''s disease (age range, 40-85; mean age, 63.2 years) and 79 healthy volunteers (age range, 18-79; mean age, 46.7 years). Results: In volunteers, experimentally induced myopia caused a substantial (>20%) reduction of the blood oxygenation level dependent (BOLD) response to a flickering dartboard. Conclusion: Refractive errors (and the resulting optical blur) may play a nonnegligible role as a possible interfering factor in fMRI experiments with visual stimuli. The MR-compatible frame (fitted with appropriate lenses) used in this study affords full refractive correction at reasonable cost and preparation time

Details

show
hide
Language(s): eng - English
 Dates: 2002-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 4182
ISI: 000174759400015
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Magnetic Resonance Imaging
  Alternative Title : J. Magn. Reson. Imaging
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 15 (1) Sequence Number: - Start / End Page: 101 - 107 Identifier: ISSN: 1053-1807