  A new design of a polysomnography-based multi-center treatment study for the restless legs syndrome

Penzel, T., Wetter, T., Lledo, A., Hundemer, H., Otto, R., Peter, J., Brandenburg, U., & Trenkwalder, C. (2002). A new design of a polysomnography-based multi-center treatment study for the restless legs syndrome. Clinical Neurophysiology, 113(4), 571-578.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : Clin. Neurophysiol.

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Penzel, T1, 著者
Wetter, TC1, 著者
Lledo, A1, 著者
Hundemer, HP1, 著者
Otto, R1, 著者
Peter, JH1, 著者
Brandenburg, U1, 著者
Trenkwalder, C1, 著者
所属:
1Max Planck Institute of Psychiatry, Max Planck Society, ou_1607137              

内容説明

表示:
非表示:
キーワード: restless legs syndrome; periodic limb movement; polysomnography; reliability; variability; multi-center treatment study
 要旨: Periodic limb movements (PLM) cause sleep disorders and daytime symptoms and are frequently associated with restless legs syndrome (RLS). Treatment of RLS with increased PLM during sleep (PLMS) has been evaluated in studies limited in size, methodology and study length. This long-term, placebo- controlled, multi-center, study with polysomnography (PSG) recordings has been designed in order to assess efficacy and safety parameters of pergolide treatment in RLS. This novel approach for a study was created to assure consistently high quality of sleep recording and analysis. Using defined criteria, 21 sleep centers were approved for the study after a pilot phase. Seventeen centers with 16 different PSG systems randomized 100 patients. Digital sleep recordings from 4 visits (baseline, 6 weeks, 6 months, I year) were submitted to one central evaluation center following previously defined standardized operating procedures. Visual scoring of all recordings was performed by one independent scorer. Reliability of scoring was evaluated for 20 randomly selected baseline recordings. The mean epoch by epoch agreement for sleep stages was 88% (range 81-96%), mean arousal re-scoring differed by 0.5 (range: - 16 to 20), and mean PLM index rescoring differed by 0.1 (range: - 1.5 to 2.1). Using one scorer with a demonstrated high reliability in PSG scoring for all sleep recordings was very effective in terms of study cost, study duration, and data quality. (C) 2002 Elsevier Science Ireland Ltd. All rights reserv

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2002-04
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): eDoc: 4172
ISI: 000175320100014
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Clinical Neurophysiology
  出版物の別名 : Clin. Neurophysiol.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -