  Toward optimized antibody microarrays: a comparison of current microarray support materials

Angenend, P., Glökler, J., Murphy, D., Lehrach, H., & Cahil, D. J. (2002). Toward optimized antibody microarrays: a comparison of current microarray support materials. Analytical Biochemistry, 309(2), 253-60.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : Anal Biochem

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Angenend, Philipp1, 著者           
Glökler, Jörn1, 著者           
Murphy, Derek2, 著者
Lehrach, Hans1, 著者           
Cahil, Dolores J.2, 著者
所属:
1Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              
2Max Planck Society, ou_persistent13              

内容説明

表示:
非表示:
キーワード: Antibody chip; Protein; Microarrays; High throughput; Diagnostics
 要旨: With the advent of protein and antibody microarray technology several different coatings and protocols have been published, which may be broadly divided into two types: gel-coated surfaces and plain non-gel-coated glass or plastic surfaces, some with chemical groups attached. We have screened 11 different array surfaces of both types and compared them with respect to their detection limit, inter- and intrachip variation, and storage characteristics. Five different antibodies were immobilized onto each type of microarray support, with total protein concentrations ranging from 40 fmol to 25 amol per spot. From these results, it was seen that some antibodies were more suited for use on antibody arrays. All measurements were performed in quadruplicate, and the results revealed high signal uniformity and reproducibility of most plain glass and plastic slides. Lower detection limits were obtained with polyacrylamide-coated slides, making them more suitable for the detection of very low concentrations of antigen. All microarray coatings could be stored for a period of 8 weeks; however, improved results were seen after 2 weeks of storage. In conclusion, the results indicate the need to test each antibody to be used on an antibody array and to select the microarray coating based on experimental requirements.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2002-10-17
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 24697
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Analytical Biochemistry
  出版物の別名 : Anal Biochem
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 309 (2) 通巻号: - 開始・終了ページ: 253 - 60 識別子(ISBN, ISSN, DOIなど): -