日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

登録内容を編集ファイル形式で保存
 
 
ダウンロード電子メール
  Quantitative PCR based expression analysis on a nanoliter scale using polymer nano-well chips

Dahl, A., Sultan, M., Jung, A., Schwartz, R., Lange, M., Steinwand, M., Livak, K. J., Lehrach, H., & Nyarsik, L. (2007). Quantitative PCR based expression analysis on a nanoliter scale using polymer nano-well chips. Biomedical Microdevices, 9(3), 307-314. doi:10.1007/s10544-006-9034-2.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : Biomed Microdevices

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Dahl, Andreas1, 著者           
Sultan, Marc2, 著者           
Jung, Alexander, 著者
Schwartz, Regine3, 著者
Lange, Matthias3, 著者
Steinwand, Michael, 著者
Livak, Kenneth J., 著者
Lehrach, Hans1, 著者           
Nyarsik, Lajos3, 著者
所属:
1Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              
2Human Chromosome 21 (Marie-Laure Yaspo), Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1479652              
3Max Planck Society, ou_persistent13              

内容説明

表示:
非表示:
キーワード: qPCR; Miniaturization; Expression analysis; Real-time detection; High density microtiterplates
 要旨: The analysis of gene expression is an essential element of functional genomics. Expression analysis is mainly based on DNA microarrays due to highly parallel readout and high throughput. Quantitative PCR (qPCR) based expression profiling is the gold standard for the precise monitoring of selected genes, and therefore used for validation of microarray data. Doing qPCR-based expression analysis in an array-like format can combine the higher sensitivity and accuracy of the qPCR methodology with a high data density at relatively low costs. This paper describes the development of an open-well based miniaturized platform for liquid PCR-based assays on the nanoliter scale using cost-effective polypropylene micro reactors (μPCR Chip). We show the quantification ability and reliability of qPCR in 200 nl with the μPCR chip down to 5 starting target molecules using TaqMan ® chemistry. An RNA expression analysis of four genes in mouse brain, liver and kidney tissues showed similar results in 200 nl as compared to standard 10 μl assays. The high sensitivity and quantification capability of the μPCR chip platform developed herein makes it a promising technology for performing high-throughput qPCR-based analysis in the nanoliter volume range.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2007-06
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Biomedical Microdevices
  出版物の別名 : Biomed Microdevices
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 9 (3) 通巻号: - 開始・終了ページ: 307 - 314 識別子(ISBN, ISSN, DOIなど): ISSN: 1387-2176