日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Characterizing the mouse ES cell transcriptome with Illumina sequencing

Rosenkranz, R., Borodina, T., Lehrach, H., & Himmelbauer, H. (2008). Characterizing the mouse ES cell transcriptome with Illumina sequencing. Genomics, 92(4), 187-194. doi:10.1016/j.ygeno.2008.05.011.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Rosenkranz, Ruben1, 著者           
Borodina, Tatiana2, 著者           
Lehrach, Hans1, 著者           
Himmelbauer, Heinz1, 著者           
所属:
1Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433550              
2Technology Development(Alexey Soldatov), Dept. of Vertebrate Genomics (Head: Hans Lehrach), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1479657              

内容説明

表示:
非表示:
キーワード: Gene expression profiling, Embryonic stem cells, Ultrashort sequence reads, Second-generation sequencing
 要旨: Large datasets generated by Illumina sequencing are ideally suited to transcriptome characterization. We generated 3,052,501 27-mer reads from F1 mouse embryonic stem (ES) cell cDNA. Using the ELAND alignment tool, 74.5% of reads matched sequenced mouse resources, < 1% were contaminants, and 3.7% failed quality control. Of the reads, 21.6% did not match mouse sequences using ELAND, but most of them were successfully aligned with mouse mRNAs using MegaBLAST. We conclude that most of the reads in the dataset are derived from mouse transcripts. A total of 14,434 mouse RefSeq genes were represented by at least 1 read. A Pearson correlation coefficient of 0.7 between Illumina sequencing and Illumina array expression data suggested similar results for both technologies. A weak 3′ bias of reads was found. Reads from genes with low expression had lower GC content than the corresponding RefSeq genes, indicating a GC bias. Biases were confirmed with further Illumina read datasets generated with cDNA from mouse brain and from mutagen-treated F1 ES cells. We calculated relative expression values, because transcript length and read number were correlated. In the absence of signal saturation or background noise, we believe that short-read sequencing technologies will have a major impact on gene expression studies in the near future.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2008-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Genomics
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 92 (4) 通巻号: - 開始・終了ページ: 187 - 194 識別子(ISBN, ISSN, DOIなど): ISSN: 0888-7543