  Real-time xCELLigence impedance analysis of the cytotoxicity of dental composite components on human gingival fibroblasts.

Urcana, E., Haertela, U., Stylloua, M., Hickel, R., Scherthan, H., & Reich, F. X. (2010). Real-time xCELLigence impedance analysis of the cytotoxicity of dental composite components on human gingival fibroblasts. Dental Materials: Official Publication of the Academy of Dental Materials, 26(1), 51-58. doi:doi:10.1016/j.dental.2009.08.007.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文
その他のタイトル : Dent Mater

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Urcana, Ebru, 著者
Haertela, Ursula, 著者
Stylloua, Marianthi, 著者
Hickel, Reinhard, 著者
Scherthan, Harry1, 著者           
Reich, Franz Xaver, 著者
所属:
1Dept. of Human Molecular Genetics (Head: Hans-Hilger Ropers), Max Planck Institute for Molecular Genetics, Max Planck Society, ou_1433549              

内容説明

表示:
非表示:
キーワード: HEMA; TEGDMA; BisGMA; UDMA; Human gingival fibroblasts; Cytotoxicity; xCELLigence system
 要旨: Objectives: Aim of this study was by continuous monitoring to assay the proliferative capacity of human gingival fibroblasts (HGFs), to investigate cytotoxicity of the most common monomers/comonomers in dental resin composites: bisphenol-A-glycidylmethacrylate (BisGMA), hydroxyethylenemethacrylate (HEMA), triethyleneglycoldimethacrylate (TEGDMA), and urethanedimethacrylate (UDMA) in HGFs during 24 h exposure using the xCELLigence system. Methods: xCELLigence cell index (CI) impedance measurements were performed according to the instructions of the supplier. HGFs were resuspended in medium and subsequently adjusted to 400,000, 200,000, 100,000, and 50,000 cells/mL. After seeding 100 μL of the cell suspensions into the wells of the E-plate 96, HGFs were monitored every 15 min for a period of up to 18 h by the xCELLigence system. Results: Half maximum effect concentrations (EC50) were determined based on the dose–response curves derived by xCELLigence measurements. Following real-time analysis, significantly increased EC50 values of HGFs exposed for 24 h to the following substances were obtained: HEMAa, TEGDMAb, UDMAc. The EC50 values (mean [mmol/L] ± S.E.M.; n = 5) were: HEMA 11.20 ± 0.3, TEGDMAa 3.61 ± 0.2, UDMAa,b 0.20 ± 0.1, and BisGMAa,b,c 0.08 ± 0.1. These results are similar to the EC50 values previously observed with the XTT end-point assay. Significance: Our data suggests that the xCELLigence live cell analysis system offers dynamic live cell monitoring and combines high data acquisition rates with ease of handling. Therefore, the xCELLigence system can be used as a rapid monitoring tool for cellular viability and be applied in toxicity testing of xenobiotics using in vitro cell cultures.