  Buffer-gas-free mass-selective ion centering in Penning traps by simultaneous dipolar excitation of magnetron motion and quadrupolar excitation for interconversion between magnetron and cyclotron motion

Rosenbusch, M., Blaum, K., Borgmann, C., Kreim, S., Kretzschmar, M., Lunney, D., Schweikhard, L., Wienholtz, F., & Wolf, R. (2012). Buffer-gas-free mass-selective ion centering in Penning traps by simultaneous dipolar excitation of magnetron motion and quadrupolar excitation for interconversion between magnetron and cyclotron motion. International Journal of Mass Spectrometry, 325-327, 51-57. doi:10.1016/j.ijms.2012.06.008.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:

作成者

表示:
非表示:
 作成者:
Rosenbusch, M.1, 著者
Blaum, Klaus2, 3, 著者           
Borgmann, Christopher2, 著者           
Kreim, Susanne2, 4, 著者           
Kretzschmar, M.5, 著者
Lunney, D.6, 著者
Schweikhard, Lutz1, 著者
Wienholtz, F.1, 著者
Wolf, R.N.1, 著者
所属:
1Institut für Physik, Ernst-Moritz-Arndt-Universität, 17487 Greifswald, Germany, ou_persistent22              
2Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              
3Physikalisches Institut, Ruprecht-Karls-Universität, 69120 Heidelberg, Germany, ou_persistent22              
4CERN, 1211 Geneva 23, Switzerland, ou_persistent22              
5Institut für Physik, Johannes Gutenberg-Universität, 55099 Mainz, Germany, ou_persistent22              
6CSNSM/IN2P3, Université de Paris Sud, 91405 Orsay, France, ou_persistent22              

内容説明

表示:
非表示:
キーワード: -
 要旨: A new excitation scheme of the radial ion-motional modes is introduced for Penning-trap ion-cyclotron-resonance experiments. By simultaneous dipolar excitation of the magnetron motion and resonant quadrupolar excitation for the conversion between magnetron motion and cyclotron motion, a mass-selective recentering of the ions of interest is performed while all other (contaminant) ions are ejected from the trap. This new technique does not rely on the application of a buffer gas as presently used [G. Savard, St. Becker, G. Bollen, H.-J. Kluge, R.B. Moore, Th. Otto, L. Schweikhard, H. Stolzenberg, U. Wiess, Physics Letters A 158 (1991) 247] and will thus prevent charge-exchange reactions and damping of the motion that decreases mass resolving power.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2012-06-23
 出版の状態: オンラインで出版済み
 ページ: 7
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 10.1016/j.ijms.2012.06.008
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: International Journal of Mass Spectrometry
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Amsterdam : Elsevier
ページ: - 巻号: 325-327 通巻号: - 開始・終了ページ: 51 - 57 識別子(ISBN, ISSN, DOIなど): ISSN: 1387-3806
CoNE: https://pure.mpg.de/cone/journals/resource/954926232412