English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector

Smith, J. R., Grote, H., Hewitson, M., Hild, S., Lück, H., Parsons, M., et al. (2005). Feedforward correction of mirror misalignment fluctuations for the GEO 600 gravitational wave detector. Classical and Quantum Gravity, 22(14), 3093-3104.

Item is

Files

show Files
hide Files
:
5_14_018.pdf (Publisher version), 305KB
Name:
5_14_018.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
eDoc_access: PUBLIC
License:
-

Locators

show

Creators

show
hide
 Creators:
Smith, J. R.1, Author
Grote, Hartmut2, Author           
Hewitson, Martin3, Author           
Hild, Stefan2, Author           
Lück, Harald2, Author           
Parsons, M., Author
Strain, Kenneth A.2, Author           
Willke, Benno2, Author           
Affiliations:
1External Organizations, ou_persistent13              
2Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24010              
3Observational Relativity and Cosmology, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society, ou_24011              

Content

show
hide
Free keywords: -
 Abstract: The core instrument of the GEO 600 gravitational wave detector is a Michelson interferometer with folded arms. The five main optics that form this interferometer are suspended in vacuum by triple pendulums with quasi-monolithic lower stages of fused silica. After installation of these pendulums in early 2003, a larger than expected coupling of longitudinal ground motion to tilt misalignment of the suspended optics was observed. Because of this, the uncontrolled misalignment of the optics during average conditions was several µrad Hz-1/2 in the frequency band around the pendulum resonance frequencies (0.5–4 Hz). In addition, it was found that longitudinal control signals applied to the intermediate pendulum stages also resulted in excessive mirror tilt. The resulting misalignment exceeded the level tolerable for stable operation of GEO 600. In order to reduce the level of mirror tilt, a bipartite feedforward system was implemented. One part feeds signals derived from seismic measurements to piezo-electric crystals in the stacks supporting the suspensions, reducing the longitudinal motion of the uppermost suspension points. The other applies tilt correction signals, derived from longitudinal control signals, to the intermediate level of the suspensions. The seismic feedforward correction reduces the root-mean-squared tilt misalignment of each main optic between 0.1 and 5 Hz by about 10 dB, typically. The intermediate-mass feedforward correction reduces the differential tilt misalignment of the Michelson interferometer by about 10 dB between 0.1 and 0.8 Hz, typically.

Details

show
hide
Language(s): eng - English
 Dates: 2005-07-21
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 251045
ISI: 000231036000020
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Classical and Quantum Gravity
  Alternative Title : Class. Quantum Gravity
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 22 (14) Sequence Number: - Start / End Page: 3093 - 3104 Identifier: ISSN: 0264-9381