Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Real-time magnetic resonance imaging of normal swallowing.

Zhang, S., Olthoff, A., & Frahm, J. (2012). Real-time magnetic resonance imaging of normal swallowing. Journal of Magnetic Resonance Imaging, 35(6), 1372-1379. doi:10.1002/jmri.23591.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1477551.pdf (Verlagsversion), 4MB
Name:
1477551.pdf
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477551-Suppl-1.mov (Ergänzendes Material), 2MB
Name:
1477551-Suppl-1.mov
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/quicktime / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477551-Suppl-2.mov (Ergänzendes Material), 953KB
Name:
1477551-Suppl-2.mov
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/quicktime / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-
:
1477551-Suppl-3.mov (Ergänzendes Material), 2MB
Name:
1477551-Suppl-3.mov
Beschreibung:
-
OA-Status:
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
video/quicktime / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-
Lizenz:
-

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Zhang, S.1, Autor           
Olthoff, A., Autor
Frahm, J.1, Autor           
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Real-time MRI; dynamic imaging; swallowing; deglutition; dysphagia
 Zusammenfassung: Purpose: To evaluate the use of a novel real-time magnetic resonance imaging (MRI) technique for the assessment of normal swallowing dynamics. Materials and Methods: In a cohort of 10 healthy subjects, real-time MRI movies at 24.3 frames per second were obtained in sagittal, coronal, and axial orientation during self-controlled swallows of 5 mL pineapple juice as oral contrast bolus. All studies were performed with the use of a commercial MRI system at 3 T combining two sets of radiofrequency receiver coils. Real-time movies relied on a fast low-angle shot (FLASH) MRI sequence with radial undersampling and image reconstruction by nonlinear inversion yielding 41.23 msec acquisition time for an in-plane resolution of 1.5 mm. Evaluations focused on clinical image quality as well as visualization and temporal quantification of distinct swallowing functions. Results: Throughout the entire process, the swallowing dynamics were well depicted and characterized with almost no visible image artifacts in all subjects. The midsagittal plane turned out to be most valuable. The movies allowed for a quantitative determination of the temporal pattern of all swallowing events. Conclusion: The proposed real-time MRI technique yields noninvasive, robust, and quantitative access to the physiology of normal swallowing in healthy subjects at high temporal resolution and image quality.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2012-01-232012
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1002/jmri.23591
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Magnetic Resonance Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 35 (6) Artikelnummer: - Start- / Endseite: 1372 - 1379 Identifikator: -