Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Sensitivity studies for specific binding reactions using the biotin/streptavidin system by evanescent optical methods

Busse, S., Scheumann, V., Menges, B., & Mittler, S. (2002). Sensitivity studies for specific binding reactions using the biotin/streptavidin system by evanescent optical methods. Biosensors & Bioelectronics, 17(8), 704-710.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Busse, S., Autor
Scheumann, V.1, Autor           
Menges, B.1, Autor           
Mittler, Silvia1, Autor           
Affiliations:
1MPI for Polymer Research, Max Planck Society, ou_1309545              

Inhalt

einblenden:
ausblenden:
Schlagwörter: evanescent wave optics; surface plasmon spectroscopy; waveguide mode spectroscopy; Mach-Zehnder interferometer; AFM; biotinstreptavidin binding; antigen-antibody binding; refractive index; thickness of swollen streptavidin
 Zusammenfassung: The combination of various evanescent optical methods such as surface plasmon spectroscopy, waveguide mode spectroscopy and an integrated optical Mach - Zelander-interferometer are used to characterize biotinylated self-assembled monolayers as well as the binding of streptavidin to these labels. The aim of designing a highly specific and sensitive, re-usable affinity sensor for antigens on the basis of an integrated optical Mach- Zehnder interferometer is based on a proper understanding of the characteristics of the entire binding matrix architecture. Therefore, a variety of biotin-derivatives immobilized in a monolayer are investigated with respect to their affinity to streptavidin and the possibility to remove the steptavidin layer specifically. The density of the streptavidin layer as well as the optical constants of the involved molecules are measured. Finally the integrated optical Mach-Zehnder interferometer is tested with respect to the sensitivity to an antigen-antibody binding reaction. An attempt to further increase the sensitivity by simultaneous detection of a fluorescence signal failed due to bleaching effects. (C) 2002 Elsevier Science B.V. All rights reserved.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2002-08
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Keine Begutachtung
 Identifikatoren: eDoc: 28288
ISI: 000176900000009
Anderer: P-02-71
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Biosensors & Bioelectronics
  Alternativer Titel : Biosens. Bioelectron.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: 17 (8) Artikelnummer: - Start- / Endseite: 704 - 710 Identifikator: ISSN: 0956-5663